Analysis of the current–voltage curves and saturation currents in burner-stabilised premixed flames with detailed ion chemistry and transport models

M Belhi, J Han, TA Casey, JY Chen, HG Im… - … Theory and Modelling, 2018 - Taylor & Francis
Current-voltage, or i–V, curves are used in combustion to characterise the ionic structure of
flames. The objective of this paper is to develop a detailed modelling framework for the …

Performance analysis of novel flue gas self-circulated burner based on low-NOx combustion

Q Xu, K Wang, J Feng, C Ding, C Yu, Z Du… - Journal of Energy …, 2020 - ascelibrary.org
A new type self-circulating structure for flue gas was designed, with a corresponding low-
nitrogen oxides (NOx) burner developed. A three-dimensional finite element model was …

Laminar non-premixed counterflow flames manipulation through the application of external direct current fields

ARD Farraj, AM Al-Naeemy, AN Al-Khateeb… - Journal of Energy …, 2017 - ascelibrary.org
Electrostatically manipulated, laminar, non-premixed, counterflow methane flames were
studied experimentally and computationally. It was established experimentally that the flame …

Bioalcohol electrosprays for practical propulsion systems

OA Al-Nuaimi, DC Kyritsis - Journal of Energy Engineering, 2019 - ascelibrary.org
Electrosprays of ethanol, 1-propanol and 1-butanol were studied experimentally at flow rates
ranging from 5 to 25 mL/h, and voltages ranging from 3 to 6 kV, spraying along and against …

Modeling counterflow combustion of dust particle cloud in heterogeneous media

M Mohammadi, M Bidabadi, H Khalili… - Journal of Energy …, 2017 - ascelibrary.org
This study investigates the counterflow combustion of an aluminum dust cloud in a
heterogeneous system of discrete heat sources. A numerical thermal model was developed …

Monitoring the Combustion Characteristic of Premixed Burners with Flame Ionization Current

F Liu, W Zhou, L Zheng, M Shao… - Journal of Energy …, 2021 - ascelibrary.org
Fully premixed burners are widely used in the field of gas boilers, and the excess air rate is a
crucial parameter to control. In this paper, a low-cost solution for monitoring the excess air …

Experimental investigation of the phenomenology of AC-driven ethanol electrosprays

H Alkaabi, DC Kyritsis - Journal of Energy Engineering, 2020 - ascelibrary.org
Ethanol alternating current (AC)-manipulated electrosprays were investigated for a
frequency range of 0.1–10 kHz; applied RMS voltages 3, 4, 5, and 6 kV RMS; and flowrates …

Electric manipulation of laminar nonpremixed counterflow propane flames

AMY Al-Naeemy, ARD Farraj… - Journal of …, 2017 - asmedigitalcollection.asme.org
The effect of the electric field on laminar nonpremixed counterflow propane flames was
analyzed computationally. The computations were conducted using ANSYS fluent platform …

[PDF][PDF] Phenomenology of AC-driven bio-alcohol electrosprays

HA Alkaabi - 2019 - khalifauniversity.elsevierpure.com
Thesis, M. Sc. in Mechanical Engineering, Department of Mechanical Engineering, Khalifa
University of Science and Technology, United Arab Emirates, October 2019. A low …