HVDC transmission: Technology review, market trends and future outlook

A Alassi, S Bañales, O Ellabban, G Adam… - … and Sustainable Energy …, 2019 - Elsevier
HVDC systems are playing an increasingly significant role in energy transmission due to
their technical and economic superiority over HVAC systems for long distance transmission …

High surge impedance loading (HSIL) lines: A review identifying opportunities, challenges, and future research needs

M Ghassemi - IEEE Transactions on Power Delivery, 2019 - ieeexplore.ieee.org
Making old new again: next generation of self-reactive power compensation high surge
impedance loading (HSIL) lines engaging transmission expansion planning (TEP) can be a …

Mitigation of half-cycle saturation of adjacent transformers during HVDC monopolar operation—Part II: Detecting zero-sequence fault currents

M Yang, D Deswal, F de Leόn - IEEE Transactions on Power …, 2019 - ieeexplore.ieee.org
This two-part paper presents a method to mitigate half-cycle saturation of transformers
caused by monopolar operation of neighboring HVDC transmission lines while keeping the …

Mitigation of half-cycle saturation of adjacent transformers during HVDC monopolar operation—Part I: Mitigation principle and device design

M Yang, D Deswal, F de Leόn - IEEE Transactions on Power …, 2019 - ieeexplore.ieee.org
When HVDC transmission systems operate in the ground return mode, transformers in
adjacent ac systems frequently suffer half-cycle saturation. In this two-part paper, an effective …

Electromagneto-mechanical numerical analysis and experiment of transformer influenced by DC bias considering core magnetostriction

X Liu, J Wu, F Jiang, Y Wang, C Zhang… - Journal of Materials …, 2020 - Springer
Abnormal vibration may cause the internal failure of transformers. In particular, the nonlinear
saturation vibration of the iron core under direct current (DC) magnetic bias will lead to …

Design and field application of dc and harmonic suppression system for neutral current in 220 kv substation

J Zhu, C Mao, B Liu, Z Wang, D Wang… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
Recently, the grounding system of substation has been seriously invaded by earth current
generated by flourishing urban rail transit network. The invasion leads to abnormal vibration …

Interval type-II fuzzy logic control of neutral DC compensation method to moderate DC bias in power transformer

OA Lasabi, AG Swanson… - SAIEE Africa Research …, 2024 - ieeexplore.ieee.org
Direct current flow through power transformers in HVDC systems can lead to significant half-
cycle saturation issues, putting the power system at risk. The HVDC system can function in …

Heuristic Control of Neutral DC Compensation Method to Moderate DC bias in Power Transformer

O Lasabi, A Swanson, L Jarvis - 2022 IEEE PES/IAS …, 2022 - ieeexplore.ieee.org
Direct currents can cause significant half-cycle saturation issues with the power transformers
used in HVDC systems, posing a serious threat to power systems. This research introduces …

Wide-Area Measurement-Driven Approaches for Power System Modeling and Analytics

H Liu - 2017 - trace.tennessee.edu
This dissertation presents wide-area measurement-driven approaches for power system
modeling and analytics. Accurate power system dynamic models are the very basis of power …

Accurate Calculation of Rotor Loss of Synchronous Condenser Based on the Big Data Analysis

A Zhang, H Xing, J Zhou - Big Data Analytics for Cyber-Physical System in …, 2020 - Springer
The synchronous condenser is used to supply reactive power for HVDC converter station
through the power transformer. The DC power that invades the power transformer biases the …