Mitigating the effects of magnetic coupling between HV transmission line and metallic pipeline using slime mould algorithm

R Djekidel, B Bentouati, MS Javaid… - Journal of Magnetism …, 2021 - Elsevier
An aerial metallic pipeline experiences induced voltage if drawn in close vicinity of a high
voltage power transmission line as suggested by Faraday's law of electromagnetic …

Examination of Electromagnetic Interference Safety Limits Caused by High Voltage Transmission Lines According to International Standards

H Duzkaya, MC Taplamacioglu… - 2024 8th …, 2024 - ieeexplore.ieee.org
The study aims to investigate electromagnetic interference types and compare them with
international standards. Railroad lines and fossil fuel transportation systems have an …

Relation between transmission lines coupling factor and over head earth wire length: its impacts on fault current distributions

M Nassereddine, J Rizk, A Hellany… - IET Generation …, 2014 - Wiley Online Library
High voltage (HV) transmission mains form important assets in electrical networks. The
existence of this infrastructure within the community necessitates effective earthing design to …

Fault current distribution and pole earth potential rise (EPR) under substation fault

M Nnassereddine, J Rizk, A Hellany… - International journal of …, 2013 - degruyter.com
New high-voltage (HV) substations are fed by transmission lines. The position of these lines
necessitates earthing design to ensure safety compliance of the system. Conductive …

[PDF][PDF] AC Interference study on piipeline: ohew split factor impacts on the induced voltage

M Nassereddine, J Rizk, A Hellany… - Journal of Electrical …, 2014 - researchgate.net
Human Safety due to electrical induced voltage is gaining more attention in the area of high
voltage sector. In existing researches, no evidence is cited on the effect that the OHEW split …

Combined effects of electrostatic and electromagnetic interferences of high voltage overhead power lines on aerial metallic pipeline

D Rabah, M Lahdeb, SSM Ghoneim… - … Series: Electronics and …, 2022 - casopisi.junis.ni.ac.rs
The main purpose of this paper is to model and analyze the electrostatic and
electromagnetic interferences between a HV overhead power line and an aerial metallic …

Induced voltage behavior on pipelines due to HV AC interference under broken OHEW

M Nassereddine, J Rizk, A Hellany… - 2015 IEEE 10th …, 2015 - ieeexplore.ieee.org
To meet the high demands on the electrical power due to the growth in populations more
high voltage projects are captured by the development scopes. To save on easement cost …

Investigation of electromagnetic interferences issues

D Stet, L Czumbil, L Ancas - 2013 8th International Symposium …, 2013 - ieeexplore.ieee.org
Electromagnetic interferences between an existing high voltage power line and a gas
stream network sharing the same right-of-way are evaluated. Induced voltages are …

[PDF][PDF] Earth potential rise (EPR) computation for a fault on transmission mains pole

M Nassereddine, J Rizk, A Hellany… - Proceedings of World …, 2012 - researchgate.net
The prologue of new High Voltage (HV) transmission mains into the community necessitates
earthing design to ensure safety compliance of the system. Conductive structures such as …

The effect of electromagnetic fields due to hv line on the parallel pipeline

CS Chai, MZA Ab Kadir, M Izadi… - … Conference on Power …, 2014 - ieeexplore.ieee.org
The effects of electromagnetic fields (EMF) due to high voltage line on the parallel pipeline
are not a common issue nowadays. The EMF will bring up some pipeline problems and …