Inerter-based structural vibration control: A state-of-the-art review

R Ma, K Bi, H Hao - Engineering Structures, 2021 - Elsevier
Structural vibration control has received considerable research attentions in the past few
decades, with special emphasis on developing effective, affordable and applicable control …

Review of vibration control strategies of high-rise buildings

MH El Ouni, M Abdeddaim, S Elias, NB Kahla - Sensors, 2022 - mdpi.com
Since the early ages of human existence on Earth, humans have fought against natural
hazards for survival. Over time, the most dangerous hazards humanity has faced are …

Experimental study and numerical modeling of nonlinear dynamic response of SDOF system equipped with tuned mass damper inerter (TMDI) tested on shaking table …

D Pietrosanti, M De Angelis, A Giaralis - International Journal of …, 2020 - Elsevier
This paper considers a novel shaking table testing campaign to assess the tuned mass-
damper-inerter (TMDI) vibrations suppression attributes in harmonically excited structures …

A generalized 2-DOF model for optimal design of MDOF structures controlled by Tuned Mass Damper Inerter (TMDI)

D Pietrosanti, M De Angelis, M Basili - International Journal of Mechanical …, 2020 - Elsevier
The paper illustrates a methodology to perform the optimal design of a Tuned Mass Damper
Inerter (TMDI) equipped on a multi degree of freedom (MDOF) structure through a …

Optimum parameters and performance of negative stiffness and inerter based dampers for base-isolated structures

NU Islam, RS Jangid - Bulletin of Earthquake Engineering, 2023 - Springer
Novel combinations of true negative stiffness dampers (NSDs) and inerter devices are used
concurrently as supplemental dampers for response control of base-isolated structures. The …

Improved model for parametric optimization of tuned mass damper-inerter for wind-induced vibration control of high-rise building

Y Quan, W Zhao, H Qiao - Structures, 2023 - Elsevier
When analyzing the wind-induced response of multi-degree-of-freedom (MDOF) structures
controlled by a tuned mass damper-inerter (TMDI), a generalized single-degree-of-freedom …

Defective two adjacent single degree of freedom systems linked by spring-dashpot-inerter for vibration control

M Basili, M De Angelis, D Pietrosanti - Engineering Structures, 2019 - Elsevier
The paper deals with the analytical formulation of two adjacent single degree of freedom
systems coupled by spring-dashpot-inerter elements adequately tuned in order to build a …

A review on the use of the inerter device in the structural coupling technique for adjacent building vibration control

A de Souza Pippi, SM Avila, G Doz - Structures, 2022 - Elsevier
Due to the large population density in big urban centers, building taller and closer buildings
is necessary. The high flexibility of these buildings can lead to excessive vibration problems …

Closed-form optimal design of the tuned inerter damper (TID) connecting adjacent flexible buildings

Z Zhang, X Li, B Chen, X Hua - Engineering Structures, 2024 - Elsevier
The tuned inerter damper (TID) is a viable solution for addressing the vibration issue of the
adjacent-building system. However, the conventional optimal calibration of the TID is …

Modal analysis and dynamic response of two adjacent single-degree-of-freedom systems linked by spring-dashpot-inerter elements

M Basili, M De Angelis, D Pietrosanti - Engineering Structures, 2018 - Elsevier
This paper illustrates the dynamics of a novel structural configuration represented by two