Virtual clinical trials in medical imaging: a review

E Abadi, WP Segars, BMW Tsui… - Journal of Medical …, 2020 - spiedigitallibrary.org
The accelerating complexity and variety of medical imaging devices and methods have
outpaced the ability to evaluate and optimize their design and clinical use. This is a …

XOP v2. 4: Recent developments of the X-ray optics software toolkit

MS del Río, RJ Dejus - … in Computational Methods for X-Ray …, 2011 - spiedigitallibrary.org
XOP v2. 4 consists of a collection of computer programs for calculation of radiation
characteristics of X-ray sources and their interaction with matter. Many of the programs …

Dedicated breast CT: radiation dose and image quality evaluation

JM Boone, TR Nelson, KK Lindfors, JA Seibert - Radiology, 2001 - pubs.rsna.org
PURPOSE: To evaluate the feasibility of breast computed tomography (CT) in terms of
radiation dose and image quality. MATERIALS AND METHODS: Validated Monte Carlo …

Further factors for the estimation of mean glandular dose using the United Kingdom, European and IAEA breast dosimetry protocols

DR Dance, KC Young… - Physics in Medicine & …, 2009 - iopscience.iop.org
Abstract The United Kingdom, European and IAEA protocols for breast dosimetry in
mammography make use of s-factors which allow for the use of different target/filter …

Tungsten anode spectral model using interpolating cubic splines: unfiltered x‐ray spectra from 20 kV to 640 kV

AM Hernandez, JM Boone - Medical physics, 2014 - Wiley Online Library
Purpose: Monte Carlo methods were used to generate lightly filtered high resolution x‐ray
spectra spanning from 20 kV to 640 kV. Methods: X‐ray spectra were simulated for a …

Spektr: a computational tool for x‐ray spectral analysis and imaging system optimization

JH Siewerdsen, AM Waese, DJ Moseley… - Medical …, 2004 - Wiley Online Library
A set of computational tools are presented that allow convenient calculation of x‐ray spectra,
selection of elemental and compound filters, and calculation of beam quality characteristics …

Glandular breast dose for monoenergetic and high-energy x-ray beams: Monte Carlo assessment

JM Boone - Radiology, 1999 - pubs.rsna.org
PURPOSE: To extend the utility of normalized glandular dose (D gN) calculations to higher x-
ray energies (up to 120 keV) and to provide the tools for investigators to calculate D gN …

Clinical digital breast tomosynthesis system: dosimetric characterization

SSJ Feng, I Sechopoulos - Radiology, 2012 - pubs.rsna.org
Purpose To comprehensively characterize the dosimetric properties of a clinical digital
breast tomosynthesis (DBT) system for the acquisition of mammographic and tomosynthesis …

Cone‐beam volume CT breast imaging: Feasibility study

B Chen, R Ning - Medical physics, 2002 - Wiley Online Library
X‐ray projection mammography, using a film/screen combination, or digital techniques, has
proven to be the most effective imaging modality currently available for early detection of …

Estimation of mean glandular dose for breast tomosynthesis: factors for use with the UK, European and IAEA breast dosimetry protocols

DR Dance, KC Young… - Physics in Medicine & …, 2010 - iopscience.iop.org
A formalism is proposed for the estimation of mean glandular dose for breast tomosynthesis,
which is a simple extension of the UK, European and IAEA protocols for dosimetry in …