Cloud storage reliability for big data applications: A state of the art survey

R Nachiappan, B Javadi, RN Calheiros… - Journal of Network and …, 2017 - Elsevier
Cloud storage systems are now mature enough to handle a massive volume of
heterogeneous and rapidly changing data, which is known as Big Data. However, failures …

存储系统中的纠删码研究综述

罗象宏, 舒继武 - 计算机研究与发展, 2012 - cqvip.com
随着海量存储系统的发展和在复杂环境中的应用, 存储系统的可靠性受到了严重的挑战.
纠删码作为存储系统容错的主要方法越来越受到重视. 首先介绍了当前典型和常见的纠删码技术 …

Flat XOR-based erasure codes in storage systems: Constructions, efficient recovery, and tradeoffs

KM Greenan, X Li, JJ Wylie - 2010 IEEE 26th symposium on …, 2010 - ieeexplore.ieee.org
Large scale storage systems require multi-disk fault tolerant erasure codes. Replication and
RAID extensions that protect against two-and three-disk failures offer a stark tradeoff …

Reconsidering single failure recovery in clustered file systems

Z Shen, J Shu, PPC Lee - 2016 46th Annual IEEE/IFIP …, 2016 - ieeexplore.ieee.org
How to improve the performance of single failure recovery has been an active research topic
because of its prevalence in large-scale storage systems. We argue that when erasure …

H-Code: A hybrid MDS array code to optimize partial stripe writes in RAID-6

C Wu, S Wan, X He, Q Cao, C Xie - 2011 IEEE International …, 2011 - ieeexplore.ieee.org
RAID-6 is widely used to tolerate concurrent failures of any two disks to provide a higher
level of reliability with the support of erasure codes. Among many implementations, one …

Hdp code: A horizontal-diagonal parity code to optimize i/o load balancing in raid-6

C Wu, X He, G Wu, S Wan, X Liu… - 2011 IEEE/IFIP 41st …, 2011 - ieeexplore.ieee.org
With higher reliability requirements in clusters and data centers, RAID-6 has gained
popularity due to its capability to tolerate concurrent failures of any two disks, which has …

Encoding-aware data placement for efficient degraded reads in XOR-coded storage systems: algorithms and evaluation

PPC Lee, J Shu, W Guo - IEEE Transactions on Parallel and …, 2018 - ieeexplore.ieee.org
Modern storage systems adopt erasure coding to maintain fault tolerance with low storage
redundancy. However, how to improve the performance of degraded reads in erasure-coded …

Tip-code: A three independent parity code to tolerate triple disk failures with optimal update complextiy

Y Zhang, C Wu, J Li, M Guo - 2015 45th Annual IEEE/IFIP …, 2015 - ieeexplore.ieee.org
With the rapid expansion of data storages and the increasing risk of data failures, triple Disk
Failure Tolerant arrays (3DFTs) become popular and widely used. They achieve high fault …

New constructions of binary MDS array codes and locally repairable array codes

J Lv, W Fang, B Chen, ST Xia… - 2022 IEEE International …, 2022 - ieeexplore.ieee.org
In this paper, we firstly present a new construction of binary maximum distance separable
(MDS) array codes, from which some types of new MDS array codes of minimum distance 4 …

Accelerate rdp raid-6 scaling by reducing disk i/os and xor operations

G Zhang, K Li, J Wang, W Zheng - IEEE Transactions on …, 2013 - ieeexplore.ieee.org
Disk additions to an RAID-6 storage system can increase the I/O parallelism and expand the
storage capacity simultaneously. To regain load balance among all disks including old and …