Cardiac 3D printing and its future directions

M Vukicevic, B Mosadegh, JK Min, SH Little - JACC: Cardiovascular …, 2017 - jacc.org
Abstract Three-dimensional (3D) printing is at the crossroads of printer and materials
engineering, noninvasive diagnostic imaging, computer-aided design, and structural heart …

Computational modeling and engineering in pediatric and congenital heart disease

AL Marsden, JA Feinstein - Current opinion in pediatrics, 2015 - journals.lww.com
Computational modeling is emerging as a crucial tool for clinical decision-making and
evaluation of novel surgical methods and interventions in pediatric cardiology and beyond …

Passive performance evaluation and validation of a viscous impeller pump for subpulmonary fontan circulatory support

W Yang, TA Conover, RS Figliola, GA Giridharan… - Scientific Reports, 2023 - nature.com
Patients with single ventricle defects undergoing the Fontan procedure eventually face
Fontan failure. Long-term cavopulmonary assist devices using rotary pump technologies are …

Respiratory effects on Fontan circulation during rest and exercise using real-time cardiac magnetic resonance imaging

Z Wei, KK Whitehead, RH Khiabani, M Tree… - The Annals of thoracic …, 2016 - Elsevier
Background It is known that respiration modulates cavopulmonary flows, but little data
compare mean flows under breath-holding and free-breathing conditions to isolate the …

Use of 3D anatomical models in mock circulatory loops for cardiac medical device testing

M Rocchi, M Ingram, P Claus, J D'hooge… - Artificial …, 2023 - Wiley Online Library
Abstract Introduction Mock circulatory loops (MCLs) are mechanical representations of the
cardiovascular system largely used to test the hemodynamic performance of cardiovascular …

The advantages of viscous dissipation rate over simplified power loss as a Fontan hemodynamic metric

ZA Wei, M Tree, PM Trusty, W Wu… - Annals of biomedical …, 2018 - Springer
Flow efficiency through the Fontan connection is an important factor related to patient
outcomes. It can be quantified using either a simplified power loss or a viscous dissipation …

In vitro assessment of right ventricular outflow tract anatomy and valve orientation effects on bioprosthetic pulmonary valve hemodynamics

NK Schiavone, CJ Elkins, DB McElhinney… - Cardiovascular …, 2021 - Springer
Purpose The congenital heart defect Tetralogy of Fallot (ToF) affects 1 in 2500 newborns
annually in the US and typically requires surgical repair of the right ventricular outflow tract …

Heart beat but not respiration is the main driving force of the systemic venous return in the Fontan circulation

DD Gabbert, C Hart, M Jerosch-Herold, P Wegner… - Scientific reports, 2019 - nature.com
The Fontan procedure provides relief from cyanosis in patients with univentricular hearts. A
major clinical unmet need is to understand whether the venous flow patterns of the Fontan …

Progress in experimental and clinical subpulmonary assistance for Fontan circulation

CR Broda, DA Taylor, I Adachi - The Journal of thoracic and cardiovascular …, 2018 - jtcvs.org
The Fontan operation was described in 1971 by Fontan and Baudet 1 to palliate tricuspid
atresia. The physiology of this anatomic reconfiguration relies on postcapillary energy and a …

Modeling patient-specific deformable mitral valves

O Ginty, J Moore, T Peters, D Bainbridge - Journal of cardiothoracic and …, 2018 - Elsevier
Medical imaging has advanced enormously over the last few decades, revolutionizing
patient diagnostics and care. At the same time, additive manufacturing has emerged as a …