Upright proton therapy for esthesioneuroblastoma: a single-institution experience

K Gordon, I Gulidov, D Smyk, A Semenov… - Frontiers in …, 2024 - frontiersin.org
Aim This study presents an analysis (efficacy and toxicity) of outcomes in patients with
esthesioneuroblastoma after pencil beam proton therapy with a fixed beamline in the upright …

Low intensity beam extraction mode on the protom synchrotron for proton radiography implementation

AA Pryanichnikov, PB Zhogolev… - Journal of Physics …, 2021 - iopscience.iop.org
Proton radiography is one of the most important and actual areas of research that can
significantly improve the quality and accuracy of proton therapy. Currently, the calculation of …

Experimental study of the target motion effect on the dose distribution in spot-scanning beam proton therapy

MA Belikhin, MS Grigoryeva, IN Zavestovskaya… - Bulletin of the Lebedev …, 2022 - Springer
This paper presents the experimental results on the intrafractional motion effect on dose
distributions in a target in the context of spot-scanning beam proton therapy. The evaluation …

Expansion of the experimental facility and development of a technique for irradiating cell cultures, based on the proton therapy complex Prometheus

IN Zavestovskaya, AE Shemyakov… - Bulletin of the Lebedev …, 2022 - Springer
Works on the optimization of the experimental stand and the development of a technique for
analyzing the biological effects of irradiation of cell cultures with a scanning proton beam of …

[PDF][PDF] // Updated Status of Proton Synchrotrons for Radiation Therapy

VE Balakin, AI Bazhan, AA Pryanichnikov… - Proc. RuPAC, 2021 - jacow.org
Abstract Physical-Technical Center of PN Lebedev Physical Institute of RAS and Protom Ltd.
are engaged in development and implantation of synchrotrons for proton therapy into clinical …

Simulation of Bragg curves produced by protons, alpha-particles, and carbon ions in water

AV Bagulya, VM Grichine, VA Ryabov… - Bulletin of the Lebedev …, 2024 - Springer
Bragg curves for protons, alpha-particles, and carbon ions in water are calculated using the
Geant4 software package. The calculation results, which are of interest for practical …

Nonanthropomorphic dynamic water phantom for spot scanning proton therapy

MA Belikhin, AA Pryanichnikov, AP Chernyaev… - Physics of Atomic …, 2022 - Springer
The capabilities of a compact nonanthropomorphic dynamic water phantom for spot
scanning proton therapy are presented. This phantom simulates the intrafractional motion of …

[HTML][HTML] Interplay Effect in Spot-Scanning Proton Therapy with Rescanning, Breath Holding, and Gating: A Phantom Study

M Belikhin, A Shemyakov, D Ivanov, I Zavestovskaya - Applied Sciences, 2024 - mdpi.com
The interplay effect is a challenge when using proton scanning beams for the treatment of
thoracic and abdominal cancers. The aim of this study was to evaluate the facility-specific …

[HTML][HTML] Commissioning of a novel gantry-less proton therapy system

J Feldman, A Pryanichnikov, A Achkienasi… - Frontiers in …, 2024 - pmc.ncbi.nlm.nih.gov
Purpose The focus of this article is to describe the configuration, testing, and commissioning
of a novel gantry-less synchrotron-based proton therapy (PT) facility. Materials and methods …

Optimization of the low-intensity beam extraction mode at the medical synchrotron for application in proton radiography and tomography

AA Pryanichnikov, AP Chernyaev, MA Belikhin… - Moscow University …, 2022 - Springer
Proton therapy is one of the rapidly developing types of radiation therapy for oncological
diseases. The use of proton imaging, a method in which the relative stopping power for …