Experimental investigation of fill pack impact on thermal-hydraulic performance of evaporative cooling tower

AV Dmitriev, IN Madyshev, VV Kharkov… - Thermal Science and …, 2021 - Elsevier
The present work deals with an experimental study of the performance of an evaporative
cooling tower (ECT) with a developed fill pack. The fill pack consists of inclined-corrugated …

[HTML][HTML] Thermal performance and emissions analysis of a new cooling tower prototype

J Ruiz, P Navarro, M Hernández, M Lucas… - Applied Thermal …, 2022 - Elsevier
The design of a wet cooling tower involves a number of trade-offs including the efficiency of
the device to remove waste heat (thermal performance) and environmental aspects …

[HTML][HTML] Experimental study of the effect of filled bed type on the performance of a cross-flow cooling tower with the approach of using water-based nanofluids …

R Javadpour, SZ Heris, JP Meyer - Energy Reports, 2022 - Elsevier
This study aimed to experimentally investigate the effects of filled beds on the performance
of a cross-flow cooling tower (CFCT) with the approach of using nanofluids. Multi-walled …

Optimizing the effect of concentration and flow rate of water/MWCNTs nanofluid on the performance of a forced draft cross-flow cooling tower

R Javadpour, SZ Heris, Y Mohammadfam - Energy, 2021 - Elsevier
Improving the performance of cooling towers has always been of interest to researchers due
to their importance and widespread use in various industries. In the present study, after …

[HTML][HTML] Effect of fill length and distribution system on the thermal performance of an inverted cooling tower

P Navarro, J Ruiz, AS Kaiser, M Lucas - Applied Thermal Engineering, 2023 - Elsevier
In the design of a cooling tower there are two key aspects, the thermal performance and
emissions level. The main objective of this paper was the experimental optimisation in terms …

[HTML][HTML] Critical evaluation of the thermal performance analysis of a new cooling tower prototype

P Navarro, J Ruiz, M Hernández, AS Kaiser… - Applied Thermal …, 2022 - Elsevier
This paper presents a critical evaluation of the thermal performance analysis of the inverted
cooling tower, which was conceived as a new cooling tower prototype that prevents the …

Water recovery efficiency improvement using the enhanced structure of the mist eliminator

Z Yu, C Sun, J Fang, L Zhang, Y Hu, B Bao, S Bu… - Process Safety and …, 2021 - Elsevier
Thermal power plants are users of high water consumption, and the water consumption of
cooling towers accounts for more than half of the total water consumption of the whole plant …

Photovoltaic Evaporative Chimney as a new alternative to enhance solar cooling

M Lucas, FJ Aguilar, J Ruiz, CG Cutillas, AS Kaiser… - Renewable energy, 2017 - Elsevier
Cooling sector plays a crucial role in the World's transition towards an efficient and
decarbonised energy system. Solar cooling is an attractive idea because of the …

The study on plume abatement and water saving of hybrid mechanical draft wet cooling tower

W Deng, F Sun, K Chen, X Zhang - Applied Thermal Engineering, 2023 - Elsevier
Under strict environmental requirements, the mechanical draft wet cooling tower (MCT)
should control the generation of plume and save water resources. In this study, the plume …

The research on plume abatement and water saving of mechanical draft wet cooling tower based on the rectangle module

W Deng, F Sun, K Chen, X Zhang - International Communications in Heat …, 2022 - Elsevier
To realize plume abatement and water saving of mechanical draft wet cooling tower (MCT),
a rectangular module with plume abatement and water saving performance is proposed in …