AAPM TG 191: Clinical use of luminescent dosimeters: TLDs and OSLDs

SF Kry, P Alvarez, JE Cygler, LA DeWerd… - Medical …, 2020 - Wiley Online Library
Thermoluminescent dosimeters (TLD) and optically stimulated luminescent dosimeters
(OSLD) are practical, accurate, and precise tools for point dosimetry in medical physics …

Dose calculation for photon‐emitting brachytherapy sources with average energy higher than 50 keV: report of the AAPM and ESTRO

J Perez‐Calatayud, F Ballester, RK Das… - Medical …, 2012 - Wiley Online Library
Purpose: Recommendations of the American Association of Physicists in Medicine (AAPM)
and the European Society for Radiotherapy and Oncology (ESTRO) on dose calculations for …

A review of brachytherapy physical phantoms developed over the last 20 years: clinical purpose and future requirements

S Wilby, A Palmer, W Polak, A Bucchi - Journal of Contemporary …, 2021 - termedia.pl
Purpose This aim of this review paper was to present information on brachytherapy
phantoms developed over the last 20 years. It offers a starting point for designing new …

Water equivalent phantom materials for 192Ir brachytherapy

AA Schoenfeld, D Harder, B Poppe… - Physics in Medicine & …, 2015 - iopscience.iop.org
Several solid phantom materials have been tested regarding their suitability as water
substitutes for dosimetric measurements in brachytherapy with 192 Ir as a typical high …

The evaluation of a 2D diode array in “magic phantom” for use in high dose rate brachytherapy pretreatment quality assurance

A Espinoza, M Petasecca, I Fuduli, A Howie… - Medical …, 2015 - Wiley Online Library
Purpose: High dose rate (HDR) brachytherapy is a treatment method that is used
increasingly worldwide. The development of a sound quality assurance program for the …

On the experimental validation of model-based dose calculation algorithms for 192Ir HDR brachytherapy treatment planning

EP Pappas, E Zoros, A Moutsatsos… - Physics in Medicine …, 2017 - iopscience.iop.org
There is an acknowledged need for the design and implementation of physical phantoms
appropriate for the experimental validation of model-based dose calculation algorithms …

Implementation of GaN based real-time source position monitoring in HDR brachytherapy

R Wang, J Ribouton, P Pittet, P Guiral, P Jalade… - Radiation …, 2014 - Elsevier
Abstract For High Dose Rate (HDR) brachytherapy Quality Assurance (QA), we propose a
seed position verification method by using two GaN dosimetric probes integrated in an …

Monte Carlo calculated microdosimetric spread for cell nucleus-sized targets exposed to brachytherapy 125I and 192Ir sources and 60Co cell irradiation

F Villegas, N Tilly, A Ahnesjö - Physics in Medicine & Biology, 2013 - iopscience.iop.org
The stochastic nature of ionizing radiation interactions causes a microdosimetric spread in
energy depositions for cell or cell nucleus-sized volumes. The magnitude of the spread may …

Evaluation of a lithium formate EPR dosimetry system for dose measurements around brachytherapy sources

L Antonovic, H Gustafsson, G Alm Carlsson… - Medical …, 2009 - Wiley Online Library
A dosimetry system using lithium formate monohydrate as detector material and electron
paramagnetic resonance (EPR) spectroscopy for readout has been used to measure …

Monte Carlo characterization of high atomic number inorganic scintillators for in vivo dosimetry in 192Ir brachytherapy

V Kaveckyte, EB Jørgensen, G Kertzscher… - Medical …, 2022 - Wiley Online Library
Background There is increased interest in in vivo dosimetry for 192Ir brachytherapy (BT)
treatments using high atomic number (Z) inorganic scintillators. Their high light output …