[HTML][HTML] Concrete walls weakened by openings as compression members: A review

C Popescu, G Sas, T Blanksvärd, B Täljsten - Engineering Structures, 2015 - Elsevier
The purpose of this paper is to review the advances that have been made in the design of
monolithic and precast reinforced concrete walls, both with and without openings, subject to …

Two-way slabs: Experimental investigation of load redistributions in steel fibre reinforced concrete

D Fall, J Shu, R Rempling, K Lundgren, K Zandi - Engineering Structures, 2014 - Elsevier
In the design of two-way reinforced concrete slabs, eg using the strip or yield line design
method, the possibility of redistributing the load between different loading directions is used …

Prediction of ultimate strength of reinforced geopolymer concrete wall panels in one-way action

N Ganesan, PV Indira, A Santhakumar - Construction and building …, 2013 - Elsevier
An experimental investigation has been carried out to study the strength and behaviour of
Ordinary Portland cement concrete (OPC) and geopolymer concrete (GPC) wall panels. A …

Behavior of axially loaded concrete wall panels with openings: an experimental study

S Fragomeni, JH Doh, DJ Lee - Advances in structural …, 2012 - journals.sagepub.com
Forty seven reinforced concrete walls with various opening configurations are tested in both
one-way and two-way action. The test panels, with a slenderness ratio of 30, 35 or 40, were …

Effect of cut-out openings on the axial strength of concrete walls

C Popescu, G Sas, C Sabău… - Journal of Structural …, 2016 - ascelibrary.org
Old structures are frequently modified to comply with current living standards and/or
legislation. Such modifications may include the addition of new windows or doors and paths …

Ultimate load formula for reinforced concrete wall panels with openings

JH Doh, S Fragomeni - Advances in Structural Engineering, 2006 - journals.sagepub.com
Reinforced concrete walls with openings are tested in both one-way and two-way action.
The test panels, with a slenderness ratio of 30 or 40, were subjected to a uniformly …

[图书][B] Experimental and theoretical studies of normal and high strength concrete wall panels with openings

DJ Lee - 2009 - researchgate.net
The simplified wall design formulae specified in the Australian (AS3600) and American
(ACI318) concrete standards are intended for the design of normal strength concrete load …

Numerical analysis of lightweight concrete wall panels having a variation of dimensions and openings that were subjected to static lateral loads

SA Nurjannah, ND Putri… - Journal of Applied …, 2022 - aseestant.ceon.rs
Wall panels are non-structural parts of buildings that are considered dead loads. The mass
of wall panels must be reduced to minimize earthquake risk and enhance structural …

Theoretical and experimental investigation of failure behavior of one-way high-strength concrete wall panels

Y Huang, E Hamed, ZT Chang… - Journal of Structural …, 2015 - ascelibrary.org
A theoretical model is developed in this paper for investigating the nonlinear behavior of one-
way high-strength reinforced concrete wall panels. The model accounts for geometric and …

Instability analysis of reinforced concrete walls with various support conditions

NM Ho, JH Doh, S Fragomeni - The Structural Design of Tall …, 2017 - Wiley Online Library
Axially loaded reinforced concrete walls can be designed using simplified design methods
given in codes such as the Australian Concrete Standard Code (AS3600‐09) and the …