Three-dimensional intravascular reconstruction techniques based on intravascular ultrasound: A technical review

C Shi, X Luo, J Guo, Z Najdovski… - IEEE journal of …, 2017 - ieeexplore.ieee.org
Intravascular ultrasound (IVUS) imaging provides two-dimensional (2-D) real-time luminal
and transmural cross-sectional images of intravascular vessels with detailed pathological …

Three-dimensional reconstruction and NURBS-based structured meshing of coronary arteries from the conventional X-ray angiography projection images

AM Vukicevic, S Çimen, N Jagic, G Jovicic, AF Frangi… - Scientific reports, 2018 - nature.com
Despite its two-dimensional nature, X-ray angiography (XRA) has served as the gold
standard imaging technique in the interventional cardiology for over five decades …

Influence of dental restorations and mastication loadings on dentine fatigue behaviour: Image-based modelling approach

AM Vukicevic, K Zelic, G Jovicic, M Djuric, N Filipovic - Journal of dentistry, 2015 - Elsevier
Objectives The aim of this study was to use Finite Element Analysis (FEA) to estimate the
influence of various mastication loads and different tooth treatments (composite restoration …

In vitro and in silico testing of partially and fully bioresorbable vascular scaffold

N Filipovic, D Nikolic, V Isailovic, M Milosevic… - Journal of …, 2021 - Elsevier
Coronary artery disease (CAD), one of the leading causes of death globally, occurs due to
the growth of atherosclerotic plaques in the coronary arteries, causing lesions which restrict …

3D catheter shape determination for endovascular navigation using a two-step particle filter and ultrasound scanning

F Chen, J Liu, H Liao - IEEE transactions on medical imaging, 2016 - ieeexplore.ieee.org
In endovascular catheter interventions, the determination of the three-dimensional (3D)
catheter shape can increase navigation information and help reduce trauma. This study …

Coupling of shear–circumferential stress pulses investigation through stress phase angle in FSI models of stenotic artery using experimental data

M Samaee, M Tafazzoli-Shadpour, H Alavi - Medical & Biological …, 2017 - Springer
Many cardiovascular diseases are closely associated with hemodynamic parameters. The
main purpose of this study is mimicking a physiological blood flow in stenotic arteries to …

Simultaneous registration of location and orientation in intravascular ultrasound pullbacks pairs via 3D graph-based optimization

L Zhang, A Wahle, Z Chen, L Zhang… - IEEE transactions on …, 2015 - ieeexplore.ieee.org
A novel method is reported for simultaneous registration of location (axial direction) and
orientation (circumferential direction) of two intravascular ultrasound (IVUS) pullbacks of the …

Registration methods for IVUS: transversal and longitudinal transducer motion compensation

GDM Talou, PJ Blanco, I Larrabide… - IEEE Transactions …, 2016 - ieeexplore.ieee.org
Objective: Intravascular ultrasound (IVUS) is a fundamental imaging technique for
atherosclerotic plaque assessment, interventionist guidance, and, ultimately, as a tissue …

Software for optimized virtual stenting of patient-specific coronary arteries reconstructed from angiography images

T Djukic, S Tomasevic, I Saveljic, A Vukicevic… - Computers in biology …, 2024 - Elsevier
Detection of clinically relevant stenosis within coronary arteries as well as planning of
treatment (stent implantation) are important topics in clinical cardiology. In this study a …

3D reconstruction of patient-specific carotid artery geometry using clinical ultrasound imaging

T Djukic, B Arsic, I Koncar, N Filipovic - Computational Biomechanics for …, 2021 - Springer
One of the techniques used to diagnose carotid artery disease is the ultrasound (US)
examination. The initiation and development of vascular diseases depends also on the flow …