An adaptive PI controller design for DC-link voltage control of single-phase grid-connected converters

M Merai, MW Naouar, I Slama-Belkhodja… - IEEE Transactions …, 2018 - ieeexplore.ieee.org
Conventionally, standard proportional and integral (PI) controllers with constant PI gains are
commonly used for the dc-link voltage control of single-phase grid-connected converters …

A voltage modulated DPC approach for three-phase PWM rectifier

Y Gui, M Li, J Lu, S Golestan… - IEEE Transactions …, 2018 - ieeexplore.ieee.org
In this paper, a voltage modulated direct power control for three-phase pulsewidth
modulated rectifier is proposed. With the suggested method, the differential equations …

Improved accuracy, modeling, and stability analysis of power-hardware-in-loop simulation with open-loop inverter as power amplifier

K Upamanyu, G Narayanan - IEEE Transactions on Industrial …, 2019 - ieeexplore.ieee.org
The accuracy of a power-hardware-in-loop (PHIL) simulation is influenced by factors such as
dynamics of the power amplifier (PA) and discretization of the real-time simulated part of the …

Advanced control of three-phase PWM rectifier using interval type-2 fuzzy neural network optimized by modified golden sine algorithm

H Acikgoz, R Coteli, E Tanyildizi, B Dandil… - Electric Power …, 2023 - Taylor & Francis
Abstract Three-phase Pulse-Width Modulated (PWM) rectifiers used between the power grid
and the load in applications requiring DC voltage have features such as high efficiency, high …

[图书][B] Power electronics-enabled autonomous power systems: next generation smart grids

QC Zhong - 2020 - books.google.com
Power systems worldwide are going through a paradigm shift from centralized generation to
distributed generation. This book presents the SYNDEM (ie, synchronized and …

Analysis and improvement of performance in LCL filter‐based PWM rectifier/inverter application using hybrid damping approach

N Mukherjee, D De - IET Power Electronics, 2013 - Wiley Online Library
A hybrid passive‐active damping solution with improved system stability margin and
enhanced dynamic performance is proposed for high power grid interactive converters. In …

A dynamic equivalent current feedforward control strategy with variable reference current in three-phase PWM rectifiers

Y Zhang, J Shan, Z Huang, T Song… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
In three-phase pulse width modulation (PWM) rectifiers, the variation of the dc side load may
be frequent and violent, and the dc bus voltage is prone to oscillate greatly. While the …

Finite-time disturbance-observer-based integral terminal sliding mode controller for three-phase synchronous rectifier

B Eskandari, A Yousefpour, M Ayati, J Kyyra… - IEEE …, 2020 - ieeexplore.ieee.org
This article is concerned with the design of a finite-time disturbance-observer-based integral
terminal sliding mode controller for the effective performance of three-phase synchronous …

Frequency tracking of digital resonant filters for control of power converters connected to public distribution systems

FD Freijedo, AG Yepes, J Malvar, O Lopez… - IET Power electronics, 2011 - IET
Resonant filters implemented in the control of grid-connected power converters should
adapt their coefficients in real time using a grid frequency estimation, for example, obtained …

A disturbance rejection-based control strategy for five-level T-type hybrid power converters with ripple voltage estimation capability

SA Khan, Y Guo, YP Siwakoti… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
This article proposes a robust control strategy for five-level T-type (5L-T) hybrid power
converters to achieve superior dynamic performance for effectively regulating the dc-bus …