2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing

BL Wilkoff, L Fauchier, MK Stiles, CA Morillo… - EP …, 2016 - academic.oup.com
Implantable cardioverter-defibrillator (ICD) therapy is clearly an effective therapy for selected
patients in definable populations. The benefits and risks of ICD therapy are directly impacted …

Late asymptomatic atrial lead perforation, a fortuitous finding during lead extraction using thoracoscopic surveillance: a case report and review of the literature

BM Van Gelder, N Verberkmoes, R Nathoe… - EP …, 2016 - academic.oup.com
A 61-year-old male patient was referred for lead extraction of an infected two-chamber
pacemaker system first implanted 18 years ago. A new atrial lead was implanted 9 years …

Video‐assisted thoracoscopic epicardial pacing: A contemporary overview

M Marini, L Pannone, S Branzoli… - Pacing and Clinical …, 2023 - Wiley Online Library
Video‐assisted thoracoscopic surgery (VATS) has revolutionized the approach and
management of pulmonary and cardiac diseases, and its applications have significantly …

Thoracoscopic implantation of epicardial left ventricular lead for cardiac resynchronization therapy

HR Kim, K Lim, SJ Park, JS Park, JY Kim… - Journal of …, 2022 - mdpi.com
(1) Background: Limited data exist on the safety and efficacy of epicardial left ventricular (LV)
lead placement using video-assisted thoracoscopic surgery (VATS) for cardiac …

Epicardial left ventricular lead implantation in cardiac resynchronization therapy patients via a video‐assisted thoracoscopic technique: Long‐term outcome

M Marini, S Branzoli, P Moggio, M Martin… - Clinical …, 2020 - Wiley Online Library
Background Epicardial placement of the left ventricular (LV) lead via a video‐assisted
thoracoscopic (VAT) approach is an alternative to the standard transvenous technique …

Video-assisted thoracoscopic pacemaker lead placement in children with atrioventricular block

S Termosesov, E Kulbachinskaya… - Annals of pediatric …, 2021 - journals.lww.com
Background: The pacemaker lead placement is presented as one of the most appropriate
procedures in children with a complete atrioventricular block (AVB). Despite the fact that …

Future of implantable devices for cardiac rhythm management

CP Lau, CW Siu, HF Tse - Circulation, 2014 - Am Heart Assoc
The first cardiac implantable electronic device (CIED), the electronic pacemaker, maintains
cardiac contraction during bradycardia. The implantable cardioverter-defibrillator (ICD) …

Effects of epicardial versus transvenous left ventricular lead placement on left ventricular function and cardiac perfusion in cardiac resynchronization therapy: a …

VF van Dijk, J Fanggiday, JC Balt… - Journal of …, 2017 - Wiley Online Library
Introduction Optimal left ventricular (LV) lead position in patients undergoing cardiac
resynchronization therapy (CRT) is crucial to achieve an optimal effect on hemodynamics …

[HTML][HTML] Observational Study of Trans-Septal Endocardial Left Ventricle Lead Implant for Effective Cardiac Resynchronization Therapy in Patients with Heart Failure …

A Farhangee, MJ Davies, K Gaughan, M Mesina… - Biomedicines, 2024 - mdpi.com
Background: When conventional trans-venous CS lead placement fails, trans-septal
endocardial left ventricle lead placement is an alternative technique used to capture the left …

[HTML][HTML] Nuevos dispositivos implantables para el manejo cardiovascular y especialmente para insuficiencia cardíaca

LL Lobo Márquez¹, RJ Bevacqua - Insuficiencia cardíaca, 2014 - SciELO Argentina
El concepto de usar un dispositivo cardíaco implantable (DCI) para el tratamiento de las
arritmias y de la insuficiencia cardíaca se inició hace más de 50 años. Desde entonces …