Experimental validation of a spectroscopic gamma-ray detector based on a LaBr3 scintillator towards real-time dose monitoring in BNCT

A Caracciolo, D Di Vita, L Buonanno… - Nuclear Instruments and …, 2022 - Elsevier
We report the experimental validation of a detection module based on a LaBr 3 (Ce+ Sr)
scintillator crystal, read by a matrix of Silicon Photomultipliers (SiPMs), for the development …

A 144-SiPM 3” LaBr3 readout module for PMTs replacement in Gamma spectroscopy

D Di Vita, L Buonanno, F Canclini, G Ticchi… - Nuclear Instruments and …, 2022 - Elsevier
A SiPM-based gamma-ray detection module for substituting bulky Photomultiplier Tubes in
the readout of large scintillation crystals is presented. The system can be coupled to …

Proof-of-concept study on a water phantom-based neutron spectrometer: Experimental test with 252Cf and 241Am-Be sources

S Manabe, H Harano, J Nishiyama - Applied Radiation and Isotopes, 2023 - Elsevier
Boron neutron capture therapy (BNCT) is a promising cancer treatment that uses energetic
ions released from 10 B (n, α) 7 Li reactions. Accurate assessment of neutron energy spectra …

Development of a High-Efficiency Device for Thermal Neutron Detection Using a Sandwich of Two High-Purity 10B Enriched Layers

C Provenzano, M Marra, AP Caricato, P Finocchiaro… - Sensors, 2023 - mdpi.com
The shortage of 3 He, a crucial element widely used as a neutron converter in neutron
detection applications, has sparked significant research efforts aimed at finding alternative …

First experimental demonstration of real-time neutron capture discrimination in helium and carbon ion therapy

M Kielly, A Caracciolo, A Chacon, J Vohradsky… - Scientific Reports, 2024 - nature.com
This work provides the first experimental proof of an increased neutron capture photon
signal following the introduction of boron to a PMMA phantom during helium and carbon ion …

A spectroscopic and imaging gamma-detector prototype towards dose monitoring in BNCT

A Caracciolo, D Di Vita, T Ferri, M Carminati… - Nuclear Instruments and …, 2023 - Elsevier
We report the performances of a compact gamma-ray detection prototype, based on a 2”
LaBr 3 scintillator crystal coupled to a matrix of 64 SiPMs, designed as a single unit for a …

An exploratory study of shielding strategies for boron neutron capture discrimination in 10B Neutron Capture Enhanced Particle Therapy

M Kielly, A Chacon, A Caracciolo, D Bolst, A Rosenfeld… - Physica Medica, 2025 - Elsevier
Purpose: To evaluate the impact of a range of shielding strategies on the rate of false
positive detections by a simulated detector for application in Neutron Capture Enhanced …

A collimator study towards BNCT-SPECT systems for dose monitoring

T Ferri, A Caracciolo, C Salvi, G Borghi… - 2022 IEEE Nuclear …, 2022 - ieeexplore.ieee.org
We report the results of a study for the design of a collimator for a BNCT-SPECT system. The
goal of the BNCT-SPECT system is to quantify and localize the dose released to a patient …

[HTML][HTML] A compact scintillator-based detector with collimator and shielding for dose monitoring in boron neutron capture therapy

A Caracciolo, T Ferri, G Borghi, M Carminati… - Physics and Imaging in …, 2024 - Elsevier
Boron neutron capture therapy exploits 10 B (n, α) 7 Li reactions for targeted tumor
destruction. In this work, we aimed at developing a dose monitoring system based on the …

Compact pixelated scintillator detector investigation for gamma ray detection

JL Wang, XG Wu, ZY He, LW Yang… - Engineering …, 2024 - iopscience.iop.org
Objective. A scintillator is a luminescent material that converts high-energy photons into
visible light and is widely used in medical imaging. Different scintillators are applied to …