Measuring biosignals with single circuit boards

G Ehrmann, T Blachowicz, SV Homburg, A Ehrmann - Bioengineering, 2022 - mdpi.com
To measure biosignals constantly, using textile-integrated or even textile-based electrodes
and miniaturized electronics, is ideal to provide maximum comfort for patients or athletes …

A novel low unity-gain frequency and low power consumption instrumentation amplifier design for RuO₂ uric acid biosensor measurement

PY Kuo, YY Chen - IEEE Transactions on Instrumentation and …, 2021 - ieeexplore.ieee.org
In this study, a novel low unity-gain frequency and low power consumption instrumentation
amplifier (UGFPCIA) was designed and applied to the readout circuit of the potentiometric …

[HTML][HTML] Seat to beat: Novel capacitive ECG integration for in-car cardiovascular measurement

J Kafková, B Babušiak, R Pirník, P Kuchár, J Kekelák… - Measurement, 2025 - Elsevier
Cardiovascular diseases (CVD) are a leading cause of global mortality, responsible for
approximately one in five deaths. In response to these concerning statistics, there is a …

A Wearable Electrostatic Sensor for Human Activity Monitoring

Y Hu, Y Yan - IEEE Transactions on Instrumentation and …, 2022 - ieeexplore.ieee.org
Human activity monitoring based on wearable sensors is important in a wide range of
biomedical and healthcare applications. Existing wearable sensors using a single unit …

Non-contact measurements of electrocardiogram and cough-associated electromyogram from the neck using in-pillow common cloth electrodes: a proof-of-concept …

A Takano, H Ishigami, A Ueno - Sensors, 2021 - mdpi.com
Asthma and chronic obstructive pulmonary disease are associated with nocturnal cough and
changes in heart rate. In this work, the authors propose a proof-of-concept non-contact …

[HTML][HTML] Common-mode voltage reduction in capacitive sensing of biosignal using capacitive grounding and DRL electrode

T Bednar, B Babusiak, M Labuda, M Smetana, S Borik - Sensors, 2021 - mdpi.com
A capacitive measurement of the biosignals is a very comfortable and unobtrusive way
suitable for long-term and wearable monitoring of health conditions. This type of sensing is …

Modeling and Analyzing the Performance of a High-impedance Analog Front End for Non-contact Bio-electricity Measurement

Z Zhou, R Wang, Y Han, Z Yang, X Shen… - IEEE Sensors …, 2024 - ieeexplore.ieee.org
The sensitivity and baseline of the analog front end (AFE) with the noncontact capacitive
probe is influenced by the skin-probe distance, thereby restricting its application of …

Physical model-based study on non-contact electrocardiogram measurement of low birth weight infants in incubators through a cloth

T Aihara, A Ueno - 2021 13th Biomedical Engineering …, 2021 - ieeexplore.ieee.org
In the measurements of low birth weight infants, some non-body-worn electrodes or sensors
are preferred because their attachment can lead to sudden change in the condition of the …

[PDF][PDF] Accelerating the healing of full-thickness excision wounds in mice using piezoelectric direct discharge plasma

MA Khalaf, SA Al-Sharqi, BM Ahmed - Iraqi Journal of Veterinary Sciences, 2024 - iasj.net
Piezoelectric Direct Discharge (PDD) plasma is a cold plasma with a floating electrode. It is
a rapidly expanding and emerging wound treatment and tissue repair technology. The …

Design and Analysis of Electrical characteristic of Non-contact Capacitive Electrode for ECG Application

RL VS, NR Raajan - 2024 - researchsquare.com
Purpose: Capacitive-based sensors have become prominent in physiological sig-nal
measurement over the past decade. The electrical characteristics of the capacitive electrode …