[HTML][HTML] Concepts and methods to assess the dynamic thermal rating of underground power cables

D Enescu, P Colella, A Russo, RF Porumb, GC Seritan - Energies, 2021 - mdpi.com
With the increase in the electrical load and the progressive introduction of power generation
from intermittent renewable energy sources, the power line operating conditions are …

An improved analytical thermal rating method for cables installed in short-conduits

G Liu, Z Xu, H Ma, Y Hao, P Wang, W Wu, Y Xie… - International Journal of …, 2020 - Elsevier
In urban underground environment, a short-conduit is commonly used to provide
mechanical protection for the cable. The cable section buried in the short-conduit may …

Thermophysical Properties of Bentonite–Sand/Fly Ash-Based Backfill Materials for Underground Power Cable

PK Sah, SS Kumar, S Sreedeep - International Journal of Thermophysics, 2023 - Springer
The surrounding (backfill) materials around the underground power cable systems are
essential for dissipating the heat away from it, during the exertion phases. The heat …

[HTML][HTML] Adaptive FEM-BPNN model for predicting underground cable temperature considering varied soil composition

AA Al-Dulaimi, MT Guneser, AA Hameed… - … Science and Technology …, 2024 - Elsevier
In underground cables of power systems, the maximum temperature of the cable is a crucial
factor in determining its capacity. According to standards, the permissible operating …

A Power System Reliability Framework Considering Soil Drying-Out Effect on Underground Cables

K Wang, K Kopsidas - IEEE Transactions on Power Systems, 2023 - ieeexplore.ieee.org
New cable installations are used to expand the power network's transmission capacity.
Considering only fundamental cable design aspects and very conservative ratings can often …

Soil Dryout in the Vicinity of Cables With Cyclic Load Installed in a Backfill

M Mróz, GJ Anders, E Gulski - IEEE Transactions on Power …, 2022 - ieeexplore.ieee.org
The IEC Standard 60287-1-1 provides the procedure for modelling of soil dryout in the
vicinity of current currying power cables. Two important assumptions limit the application of …

基于磁热流多场耦合的双沟四回路电缆温度场分布与载流量计算.

刘刚, 许志锋, 王鹏宇, 黄世杰… - Journal of South …, 2020 - search.ebscohost.com
式中: x, y 为二维几何模型中的坐标位置; n 为边界外法线方向; Γ 为区域边界; T 为温度, K; Tf
为外界环境温度, K; k 为介质导热系数, W/(m· K); q 为热流密度, W/m2; h 为表层空气的对流换热 …

Comparison of two laboratory methods for measuring soil critical temperature

H Oh, JM Tinjum - Geotechnical Testing Journal, 2021 - asmedigitalcollection.asme.org
Coupled heat and moisture transfer above a critical temperature is important in various
geothermal applications (eg, geothermal heat exchangers, buried power cables, and energy …

Effect of Initial Moisture Content on Critical Temperature of Three Sandy Soils

H Oh, JM Tinjum - Geo-Congress 2020, 2020 - ascelibrary.org
Once soil temperature reaches a critical temperature due to heat generated from a heat
source (eg, ground-based heat exchangers, buried electrical cables), moisture migration is …

Experimental study on the effect of soil moisture content on critical temperature rise for typical cable backfill materials

K Rieksts, E Eberg - IEEE Transactions on Power Delivery, 2022 - ieeexplore.ieee.org
The increased utilization of power grid requires operating power cables close to their
thermal limit. Buried power cables in such condition experience thermal instability where …