[HTML][HTML] Seismic upgrading of existing reinforced concrete buildings: A state-of-the-art review

PD Gkournelos, TC Triantafillou, DA Bournas - Engineering Structures, 2021 - Elsevier
Collapses or serious damages of existing buildings during strong earthquakes have resulted
in significant economic losses, severe injuries and loss of human lives. Given the late …

[PDF][PDF] Seismic design of masonry and reinforced concrete infilled frames: a comprehensive overview

ML Moretti - American Journal of Engineering and Applied …, 2015 - researchgate.net
Despite the extensive research on the seismic behavior of infilled frames since 1960's, there
is no general consensus towards a unified approach. Purpose of this study is to review the …

Effectiveness of structural walls in improving the serviceability of a seismically-retrofitted RC building

A Şimşek, Ö Yurdakul, B Duran, O Tunaboyu… - Bulletin of Earthquake …, 2023 - Springer
A moderate earthquake with a magnitude M w of 6.8 hit the Elazig Province of Turkey on
January 24th, 2020, causing fatalities and structural damage/failure. Following the …

Strengthening masonry infill walls with reinforced plaster

S Altın, Ö Anıl, Y Kopraman… - Proceedings of the …, 2010 - icevirtuallibrary.com
One technique for strengthening masonry infill walls against seismic lateral forces permitted
by the Turkish Seismic Code is to add a plaster layer with mesh reinforcement to one face of …

Experimental behavior of strengthening of masonry infilled reinforced concrete frames by adding rebar‐reinforced stucco

F Kaya, H Tekeli, Ö Anil - Structural Concrete, 2018 - Wiley Online Library
Strengthening of structures may become a necessity to overcome the mistakes made during
the design and construction phases of existing reinforced concrete (RC) buildings. In recent …

Design of reinforced concrete infilled frames

ML Moretti, T Papatheocharis… - Journal of Structural …, 2014 - ascelibrary.org
The work presented in this paper aimed to evaluate the diagonal strut model for the design
of reinforced concrete (RC) infilled frames, already broadly used as a design tool in the case …

Strength and ductility type retrofit of soft-first-story RC frames through the steel-jacketed non-reinforced thick hybrid wall

P Javadi, T Yamakawa - Engineering Structures, 2019 - Elsevier
In this paper, a new technique is proposed for retrofitting low-rise soft-first-story reinforced
concrete buildings. The proposed retrofitting technique is called “Thick Hybrid Wall”. In this …

Pseudo-dynamic tests on a full-scale four-storey reinforced concrete frame seismically retrofitted with reinforced concrete infilling

CZ Chrysostomou, M Poljansek… - Structural …, 2013 - Taylor & Francis
The effectiveness of seismic retrofitting of multi-storey multi-bay reinforced concrete (RC)-
frame buildings by converting selected bays into new walls through infilling with RC was …

Eurocode-based seismic assessment of modern heritage RC structures: The case of the Tower of the Nations in Naples (Italy)

F De Luca, GM Verderame, G Manfredi - Engineering structures, 2014 - Elsevier
Given the interest earned recently by modern heritage structures, seismic assessment
criteria of Eurocode 8 for ordinary reinforced concrete structures are applied to a modern …

Experimental study on existing reinforced concrete frames strengthened by L-type precast concrete wall panels to earthquake-proof buildings

SK Ha, SY Yu, JS Kim - KSCE Journal of Civil Engineering, 2018 - Springer
The purpose of this study is to investigate the behavior of existing Reinforced Concrete (RC)
frames strengthened with L-type Precast Concrete (PC) wall panels under cyclic loads. The …