Distribution of axial length and ocular biometry measured using partial coherence laser interferometry (IOL Master) in an older white population

R Fotedar, JJ Wang, G Burlutsky, IG Morgan, K Rose… - Ophthalmology, 2010 - Elsevier
PURPOSE: We aimed to describe norms for the distribution of axial length (AL) and other
ocular biometric parameters in an older Caucasian population, measured using partial …

Comparison of 2 laser instruments for measuring axial length

KJ Hoffer, HJ Shammas, G Savini - Journal of Cataract & Refractive Surgery, 2010 - Elsevier
PURPOSE: To compare axial length (AL), anterior chamber depth (ACD), and keratometric
(K) measurements of 2 laser biometers. SETTING: Private practices, Lynwood and Santa …

Biometry and intraocular lens power calculation results with a new optical biometry device: comparison with the gold standard

G Kaswin, A Rousseau, M Mgarrech, E Barreau… - Journal of Cataract & …, 2014 - Elsevier
Purpose To evaluate the agreement in axial length (AL), keratometry (K), anterior chamber
depth (ACD) measurements; intraocular lens (IOL) power calculations; and predictability …

Change in choroidal thickness and axial length with change in intraocular pressure after trabeculectomy

O Saeedi, A Pillar, J Jefferys, K Arora… - British Journal of …, 2014 - bjo.bmj.com
Background/aims We studied the change in choroidal thickness (CT) and axial length (AL)
after intraocular (IOP) changes produced by trabeculectomy. Methods Twenty-one eyes of …

Comparison of a new optical biometer using swept-source optical coherence tomography and a biometer using optical low-coherence reflectometry

KJ Hoffer, PC Hoffmann, G Savini - Journal of Cataract & Refractive Surgery, 2016 - Elsevier
Purpose To investigate agreement between the IOLMaster 700 based on swept-source
optical coherence tomography (SS-OCT) and the Lenstar LS 900 based on optical low …

[HTML][HTML] Comparison of Magnetic Resonance Imaging–Based and Conventional Measurements for Proton Beam Therapy of Uveal Melanoma

MG Jaarsma-Coes, TA Ferreira, M Marinkovic… - Ophthalmology …, 2023 - Elsevier
Objective Conventionally, ocular proton therapy (PT) is planned using measurements
obtained by an ophthalmologist using ultrasound, fundoscopy, biometry, and intraoperative …

Repeatability and reproducibility of biometry and keratometry measurements using a noncontact optical low-coherence reflectometer and keratometer

HJ Shammas, KJ Hoffer - American journal of ophthalmology, 2012 - Elsevier
PURPOSE: To evaluate the repeatability, reproducibility, or both of the biometry and
keratometry measurements obtained by a new optical low-coherence reflectometer and …

[HTML][HTML] Age, gender, corneal diameter, corneal curvature and central corneal thickness in Nigerians with normal intra ocular pressure

E Iyamu, E Osuobeni - Journal of optometry, 2012 - Elsevier
Purpose To investigate the relationship between age, gender, corneal diameter, central
corneal curvature, central corneal thickness (CCT) and intraocular pressure in Nigerians …

Ocular biometry in an urban Indian population: the Singapore Indian Eye Study (SINDI)

CW Pan, TY Wong, L Chang, XY Lin… - … & visual science, 2011 - iovs.arvojournals.org
Purpose.: To describe the distribution and determinants of ocular biometric parameters in
adult Singapore Indians. Methods.: A population-based, cross-sectional study was …

Predicting the refractive outcome and accuracy of IOL power calculation after phacoemulsification using the SRK/T formula with ultrasound biometry in medium axial …

Y Karabela, M Eliacik, MS Kocabora… - Clinical …, 2017 - Taylor & Francis
Purpose To evaluate the accuracy of the SRK/T formula using ultrasound (US) biometry in
predicting a target postoperative refraction of±1.00 D in eyes with medium axial length (AL) …