Direct power control of a three-phase inverter for grid input current shaping of a single-phase diode rectifier with a small DC-link capacitor

Y Son, JI Ha - IEEE Transactions on Power Electronics, 2014 - ieeexplore.ieee.org
This paper describes motor drive system fed by a single-phase diode rectifier without power
factor correction (PFC) circuit or the input filter. The system considered in this paper consists …

Optimal variable switching frequency scheme to reduce loss of single-phase grid-connected inverter with unipolar and bipolar PWM

Y Xia, J Roy, R Ayyanar - … of Emerging and Selected Topics in …, 2019 - ieeexplore.ieee.org
Reducing the power loss of a converter without increasing its volume or cost in hardware
has always been a much sought-after but challenging goal. This article proposes a …

A novel DC-link voltage feedback active damping control method for IPMSM drives with small DC-link capacitors

H Li, Q Yin, Q Wang, H Luo… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
In a small dc-link drive system, the LC resonance is a typical phenomenon caused by the
negative inverter admittance related to the constant power load, which is considered an …

Single-phase grid-connected motor drive system with DC-link shunt compensator and small DC-link capacitor

H Shin, YH Chae, Y Son, JI Ha - IEEE Transactions on Power …, 2016 - ieeexplore.ieee.org
The single-phase diode rectifier system with small dc-link capacitor shows wide diode
conduction time and it improves the grid current harmonics. By shaping the output power …

Discontinuous grid current control of motor drive system with single-phase diode rectifier and small DC-link capacitor

Y Son, JI Ha - IEEE Transactions on Power Electronics, 2016 - ieeexplore.ieee.org
In this paper, a control method for motor drive system without electrolytic capacitor is
proposed. Since dc-link capacitor of this motor drive is about 1% of the conventional one, it …

Grid current shaping method with DC-link shunt compensator for three-phase diode rectifier-fed motor drive system

H Shin, Y Son, JI Ha - IEEE Transactions on Power Electronics, 2016 - ieeexplore.ieee.org
This paper proposes grid current shaping method using dc-link shunt compensator for three-
phase diode rectifier system without electrolytic dc-link capacitor. In the proposed method …

A YD multifunction balance transformer-based power quality control system for single-phase power supply system

S Hu, Y Li, B Xie, M Chen, Z Zhang… - IEEE Transactions …, 2015 - ieeexplore.ieee.org
This paper proposes a YD multifunction balance transformer (YD-MFBT)-based power
quality control system (MBT-PQCS) to deal with the power quality problems in the single …

A modular power converter with active front-end system to mitigate harmonics in distribution networks

A Alduraibi, J Yaghoobi… - IEEE Journal of …, 2020 - ieeexplore.ieee.org
Power quality improvement of power electronics systems in many applications such as
adjustable speed drive (ASD) is vital due to the high penetration of grid-connected …

Enhanced phase-shifted current control for harmonic cancellation in three-phase multiple adjustable speed drive systems

Y Yang, P Davari, F Zare… - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
A phase-shifted current control can be employed to mitigate certain harmonics induced by
the diode rectifiers and silicon-controlled rectifiers as the front ends of multiple parallel …

Survey and Analysis for High Power Factor IPMSM Drive System Using Electrolytic Capacitor‐Less Inverter

K Ohishi, H Haga, K Abe - IEEJ Transactions on Electrical and …, 2024 - Wiley Online Library
Home appliances such as residential air conditioners are based on the variable speed
drives for AC motors such as IPMSM and IM. These variable speed drives always require the …