Grid-synchronization stability of converter-based resources—An overview

X Wang, MG Taul, H Wu, Y Liao… - IEEE Open Journal …, 2020 - ieeexplore.ieee.org
This paper presents an overview of the synchronization stability of converter-based
resources under a wide range of grid conditions. The general grid-synchronization …

HVDC transmission: Technology review, market trends and future outlook

A Alassi, S Bañales, O Ellabban, G Adam… - … and Sustainable Energy …, 2019 - Elsevier
HVDC systems are playing an increasingly significant role in energy transmission due to
their technical and economic superiority over HVAC systems for long distance transmission …

Transient stability of voltage-source converters with grid-forming control: A design-oriented study

D Pan, X Wang, F Liu, R Shi - IEEE Journal of Emerging and …, 2019 - ieeexplore.ieee.org
Driven by the large-scale integration of distributed power resources, grid-connected voltage-
source converters (VSCs) are increasingly required to operate as grid-forming units to …

Current limiting control with enhanced dynamics of grid-forming converters during fault conditions

MG Taul, X Wang, P Davari… - IEEE Journal of Emerging …, 2019 - ieeexplore.ieee.org
With an increasing capacity in the converter-based generation to the modern power system,
a growing demand for such systems to be more grid-friendly has emerged. Consequently …

Subsynchronous interaction between direct-drive PMSG based wind farms and weak AC networks

H Liu, X Xie, J He, T Xu, Z Yu, C Wang… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
Recently, sustained power oscillation at subsynchronous frequency was captured in direct-
drive permanent magnetic synchronous generator (PMSG) based wind farms in Xinjiang …

An overview of assessment methods for synchronization stability of grid-connected converters under severe symmetrical grid faults

MG Taul, X Wang, P Davari… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
Grid-connected converters exposed to weak grid conditions and severe fault events are at
risk of losing synchronism with the external grid and neighboring converters. This …

Large signal synchronizing instability of PLL-based VSC connected to weak AC grid

Q Hu, L Fu, F Ma, F Ji - IEEE Transactions on Power Systems, 2019 - ieeexplore.ieee.org
Similar large signal synchronizing instability that is common in traditional power system also
exists in voltage source converter (VSC) dominated power system, which is increasingly …

Impact of power grid strength and PLL parameters on stability of grid-connected DFIG wind farm

J Liu, W Yao, J Wen, J Fang, L Jiang… - IEEE Transactions …, 2019 - ieeexplore.ieee.org
This paper investigates the impact of powergrid strength and phase-locked loop (PLL)
parameters on small signal stability of grid-connected doubly fed induction generator (DFIG) …

Impact of short-circuit ratio and phase-locked-loop parameters on the small-signal behavior<? pub _bookmark="" command="[quick mark]"?> of a vsc-hvdc converter

JZ Zhou, H Ding, S Fan, Y Zhang… - IEEE Transactions on …, 2014 - ieeexplore.ieee.org
The impact of phase-locked loop (PLL) parameters on the dynamic and steady-state
behavior of a voltage-source converter (VSC) in an HVDC transmission system is …

Design-oriented transient stability analysis of grid-connected converters with power synchronization control

H Wu, X Wang - IEEE Transactions on Industrial Electronics, 2018 - ieeexplore.ieee.org
The power synchronization control (PSC) has been increasingly used with voltage-source
converters (VSCs) connected to the weak ac grid. This paper presents an in-depth analysis …