[HTML][HTML] THE POTENTIAL OF Ti-6Al-7Nb, AND DESIGN FOR MANUFACTURING CONSIDERATIONS IN MITIGATING FAILURE OF HIP IMPLANTS IN SERVICE.

K Posiyano, RVS Prasad, TC Dzogbewu… - Biomedical Engineering …, 2024 - Elsevier
The hip prosthesis, used to repair or recreate the diseased or damaged hip joint's
articulation functionality, greatly influences the outcome of total hip arthroplasty (THA) …

Static structural analysis of the effect of change in femoral head sizes used in Total Hip Arthroplasty using finite element method

AK Bhawe, KM Shah, S Somani, S Shenoy B… - Cogent …, 2022 - Taylor & Francis
The total hip prosthesis is considered one of the greatest advancements in orthopaedic
surgery in the early 20th century. In hip implant replacement, the stem is inserted into the …

Performance of textured dual mobility total hip prosthesis with a concave dimple during Muslim prayer movements

M Muchammad, M Tauviqirrahman, MI Ammarullah… - Scientific Reports, 2024 - nature.com
The single mobility bearing as a previous bearing design of total hip prosthesis has severe
mobility constraints that can result in dislocation during Muslim (people who follow the Islam …

A Review of Enhanced Total Hip Prosthesis Design and Material Bearing Combination to Accommodate Muslim Prayer (Salat) Movements: Biomechanical …

MI Ammarullah, M Kozin, MI Maula, MDP Lamura… - Tribology …, 2025 - Elsevier
Total hip prostheses have greatly improved mobility and quality of life for patients with hip
disorders. However, the unique biomechanical demands of Muslim prayer (Salat), involving …

Fatigue life evaluation of different hip implant designs using finite element analysis

JV Corda, KN Chethan, S Shenoy… - Journal of Applied …, 2023 - aseestant.ceon.rs
Fatigue failure is one of the causes of the failure of hip implants. The main objective of this
work is to carry out fatigue failure analysis on different hip profiles and compare the …

[HTML][HTML] A method for estimating the contact area of a dual-mobility total hip prosthesis

T Hidayat, MI Ammarullah, E Saputra, M Lamura, C KN… - AIP Advances, 2024 - pubs.aip.org
The term “contact area” refers to the total surface area of two entities in direct physical touch.
When discussing an artificial hip joint,“contact area” refers to the surface area of contact …

Numerical comparison of the intramedullary nail for the fixation of different proximal femoral fractures

YN Chen, CW Chang, KC Su, CJ Chang - Clinical Biomechanics, 2025 - Elsevier
Background This study aimed to compare the mechanical responses, including the stability
and implant stress, of different proximal femoral fractures stabilized with an intramedullary …

[HTML][HTML] Integrating finite element analysis in total hip arthroplasty for childhood hip disorders: Enhancing precision and outcomes

MI Ammarullah - World Journal of Orthopedics, 2025 - wjgnet.com
Total hip arthroplasty for adults with sequelae from childhood hip disorders poses significant
challenges due to altered anatomy. The paper published by Oommen et al reviews the …

Identification of the effective crane hook's cross-section by incorporating finite element method and programming language

MNH Dipu, MH Apu, PP Chowdhury - Heliyon, 2024 - cell.com
The crane hook is a widely utilized component in several industries for the purpose of lifting
things. The crane hook must possess the capacity to withstand the intended load without …

The computational approach to predicting wear: comparison of wear performance of CFR-PEEK and XLPE liners in total hip replacement

AT Alpkaya, Ş Mihçin - Tribology Transactions, 2023 - Taylor & Francis
Wear on articulating bearing surfaces is a key factor causing revision in total hip
replacement (THR). Wear debris that releases particles from bearing surfaces might result in …