Present state and issues in IORT physics

FW Hensley - Radiation Oncology, 2017 - Springer
Literature was reviewed to assess the physical aspects governing the present and emerging
technologies used in intraoperative radiation therapy (IORT). Three major technologies were …

Electronic brachytherapy—current status and future directions

DJ Eaton - The British journal of radiology, 2015 - academic.oup.com
In the past decade, electronic brachytherapy (EB) has emerged as an attractive modality for
the treatment of skin lesions and intraoperative partial breast irradiation, as well as finding …

AAPM WGDCAB Report 372: A joint AAPM, ESTRO, ABG, and ABS report on commissioning of model‐based dose calculation algorithms in brachytherapy

L Beaulieu, F Ballester, D Granero… - Medical …, 2023 - Wiley Online Library
The introduction of model‐based dose calculation algorithms (MBDCAs) in brachytherapy
provides an opportunity for a more accurate dose calculation and opens the possibility for …

Model-based dose calculation algorithms for brachytherapy dosimetry

SA Enger, J Vijande, MJ Rivard - Seminars in radiation oncology, 2020 - Elsevier
The purpose of this study was to review the limitations of dose calculation formalisms for
photon-emitting brachytherapy sources based on the American Association of Physicists in …

GEANT4 for breast dosimetry: parameters optimization study

C Fedon, F Longo, G Mettivier… - Physics in Medicine & …, 2015 - iopscience.iop.org
Mean glandular dose (MGD) is the main dosimetric quantity in mammography. MGD
evaluation is obtained by multiplying the entrance skin air kerma (ESAK) by normalized …

[HTML][HTML] Modern tools for modern brachytherapy

D Berger, S Van Dyk, L Beaulieu, T Major, T Kron - Clinical Oncology, 2023 - Elsevier
This review aims to showcase the brachytherapy tools and technologies that have emerged
during the last 10 years. Soft-tissue contrast using magnetic resonance and ultrasound …

RapidBrachyMCTPS: a Monte Carlo-based treatment planning system for brachytherapy applications

G Famulari, MA Renaud, CM Poole… - Physics in Medicine …, 2018 - iopscience.iop.org
Despite being considered the gold standard for brachytherapy dosimetry, Monte Carlo (MC)
has yet to be implemented into a software for brachytherapy treatment planning. The …

An investigation into the INTRABEAM miniature x‐ray source dosimetry using ionization chamber and radiochromic film measurements

PGF Watson, H Bekerat… - Medical …, 2018 - Wiley Online Library
Purpose Intraoperative radiotherapy using The INTRABEAM System (Carl Zeiss Meditec AG,
Jena, Germany), a miniature low‐energy x‐ray source, has proven to be an effective …

The influence of tissue composition uncertainty on dose distributions in brachytherapy

D Mann-Krzisnik, F Verhaegen, SA Enger - Radiotherapy and Oncology, 2018 - Elsevier
Background and purpose Model-based dose calculation algorithms (MBDCAs) have
evolved from serving as a research tool into clinical practice in brachytherapy. This study …

In vivo dosimetry in low-voltage IORT breast treatments with XR-RV3 radiochromic film

S Lozares, JA Font, A Gandía, A Campos… - Physica Medica, 2021 - Elsevier
Purpose The objectives of the study were to establish a procedure for in vivo film-based
dosimetry for intraoperative radiotherapy (IORT), evaluate the typical doses delivered to …