AC microgrid protection schemes: A comprehensive review

WM Hamanah, MI Hossain, M Shafiullah… - IEEE Access, 2023 - ieeexplore.ieee.org
The power grid infrastructure has evolved from a centralized to a distributed model utilizing
renewable energy sources in the last few years. This trend is likely to continue, given the …

Fault current limiters in power systems: A comprehensive review

MS Alam, MAY Abido, I El-Amin - Energies, 2018 - mdpi.com
Power systems are becoming more and more complex in nature due to the integration of
several power electronic devices. Protection of such systems and augmentation of reliability …

On the advance of SFCL: a comprehensive review

MR Barzegar‐Bafrooei, A Akbari Foroud… - IET Generation …, 2019 - Wiley Online Library
This study aims to provide a comprehensive review of various superconducting fault current
limiters (SFCLs) configurations. Regarding the applied technology, the different types of …

Analysis of impacts of superconducting fault current limiter (SFCL) placement on distributed generation (DG) expansion

Y Kim, HC Jo, SK Joo - IEEE Transactions on Applied …, 2016 - ieeexplore.ieee.org
The placement of the superconducting fault current limiter (SFCL) can be utilized to
accommodate the increasing integration of distributed generations (DGs) in a power system …

Coordination of overcurrent protection relays in networks with superconducting fault current limiters

W Rebizant, K Solak, B Brusilowicz, G Benysek… - International Journal of …, 2018 - Elsevier
The paper concerns coordination of overcurrent (OC) protection relays in power networks
with superconducting fault current limiters (SFCL). At the beginning, information about …

The TRV improvement of fast circuit breakers using solid-state series superconducting reactor

A Heidary, M Yazdani-Asrami… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
Utilizing superconducting technology in fault current limiters for power grid applications is a
practical solution to achieve a more modern and efficient power system. This is due to their …

Experimental results of a 15 kV, 140 A superconducting fault current limiter

J Kozak, M Majka, S Kozak - IEEE Transactions on Applied …, 2017 - ieeexplore.ieee.org
This paper presents the design and experimental results of a coreless superconducting fault
current limiter (SFCL). The limiter has a rating of 15 kV and 140 A and was tested with a 2.5 …

HTS tapes selection for superconducting current limiters

M Majka, J Kozak, S Kozak - IEEE Transactions on Applied …, 2017 - ieeexplore.ieee.org
The superconducting fault current limiters (SFCLs) are highly effective solutions to reduce
fault current in electric power system. The process of quenching may occur in all …

Forces and Stresses in the Windings of a Superconducting Fault Current Limiter

J Kozak - Energies, 2022 - mdpi.com
This paper presents the design of a Superconducting Fault Current Limiter (SFCL) and
calculation results of forces and stresses in the windings of a resistive fault current limiter …

Study of fault current limiter—a survey

KB Yadav, A Priyadarshi, S Shankar… - Innovations in Electrical …, 2021 - Springer
The requirement of electric energy is gaining pace in day-to-day life. Due to which,
distributed energy source (DES) has been introduced in power sector. But while connecting …