[HTML][HTML] A numerical modelling of an amperometric-enzymatic based uric acid biosensor for GOUT arthritis diseases

P Parthasarathy, S Vivekanandan - Informatics in Medicine Unlocked, 2018 - Elsevier
A numerical model of an amperometric-enzymatic uric acid biosensor for a non-relentless
condition has been developed. This model depends on the arrangement of nonlinear …

[HTML][HTML] Incorporating different enzyme kinetics in amperometric biosensor for the steady-state conditions: A complete theoretical and numerical approach

JA Vinayagan, SM Krishnan, L Rajendran… - International Journal of …, 2024 - Elsevier
The well-defined physical, chemical, and biological interactions that define the behaviour of
biosensors are described by nonlinear differential equations. Because these biosensors …

[HTML][HTML] Theoretical analysis of the steady-state responses of an innovative general flexible enzyme-electrode in potentiometric biosensors

JA Vinayagan, P Jeyabarathi, L Rajendran… - International Journal of …, 2024 - Elsevier
A mathematical model of potentiometric enzyme electrodes of general shape for a steady-
state condition has been proposed. Two nonlinear reaction-diffusion equations for the …

Theoretical treatment and numerical simulation of potentiometric and amperometric enzyme electrodes and of enzyme reactors: Part 1: steady-state concentration …

WE Morf, PD Van Der Wal, E Pretsch… - Journal of …, 2011 - Elsevier
A unified and comparative treatment of traditional potentiometric and amperometric enzyme
electrodes and of enzyme reactors is presented. Exact theoretical descriptions are given for …

[PDF][PDF] Mathematical modelling of an enzyme-based biosensor

I Ismail, G Oluleye, I Oluwafemi… - Int. J. Biosens …, 2017 - researchgate.net
The behavior of biosensors lies on a well-defined physical, chemical and biological
reactions, which are specified by nonlinear differential equations. These biosensors have …

Analysis of mathematical modelling on potentiometric biosensors

N Mehala, L Rajendran - International Scholarly Research …, 2014 - Wiley Online Library
A mathematical model of potentiometric enzyme electrodes for a nonsteady condition has
been developed. The model is based on the system of two coupled nonlinear time …

[HTML][HTML] A numerical modelling of an amperometric-enzymatic based uric acid biosensor for GOUT arthritis diseases

P Parthasarathy, S Vivekanandan - Informatics in Medicine Unlocked, 2019 - Elsevier
A numerical model of an amperometric-enzymatic uric acid biosensor for a non-relentless
condition has been developed. This model depends on the arrangement of nonlinear …

[引用][C] Computational modeling of amperometric choline biosensor for neurochemical detection.

P Ravikumar, S Arumugam, N Jeyashanthi - Biomedical Research (0970-938X), 2016