A general framework and review of scatter correction methods in x‐ray cone‐beam computerized tomography. Part 1: scatter compensation approaches

EP Rührnschopf, K Klingenbeck - Medical physics, 2011 - Wiley Online Library
Since scattered radiation in cone‐beam volume CT implies severe degradation of CT
images by quantification errors, artifacts, and noise increase, scatter suppression is one of …

Characterization of the homogeneous tissue mixture approximation in breast imaging dosimetry

I Sechopoulos, K Bliznakova, X Qin, B Fei… - Medical …, 2012 - Wiley Online Library
Purpose: To compare the estimate of normalized glandular dose in mammography and
breast CT imaging obtained using the actual glandular tissue distribution in the breast to that …

CT energy weighting in the presence of scatter and limited energy resolution

TG Schmidt - Medical physics, 2010 - Wiley Online Library
Purpose: Energy‐resolved CT has the potential to improve the contrast‐to‐noise ratio (CNR)
through optimal weighting of photons detected in energy bins. In general, optimal weighting …

X-ray scatter estimation using deep splines

P Roser, A Birkhold, A Preuhs, C Syben… - … on Medical Imaging, 2021 - ieeexplore.ieee.org
X-ray scatter compensation is a very desirable technique in flat-panel X-ray imaging and
cone-beam computed tomography. State-of-the-art U-net based scatter removal approaches …

A novel hardware duo of beam modulation and shielding to reduce scatter acquisition and dose in cone‐beam breast CT

P Ghazi, S Youssefian, T Ghazi - Medical physics, 2022 - Wiley Online Library
Purpose In cone‐beam breast CT, scattered photons form a large portion of the acquired
signal, adversely impacting image quality throughout the frequency response of the imaging …

X‐ray scatter correction method for dedicated breast computed tomography

I Sechopoulos - Medical physics, 2012 - Wiley Online Library
Purpose: To improve image quality and accuracy in dedicated breast computed tomography
(BCT) by removing the x‐ray scatter signal included in the BCT projections. Methods: The …

Shading artifact correction in breast CT using an interleaved deep learning segmentation and maximum‐likelihood polynomial fitting approach

P Ghazi, AM Hernandez, C Abbey, K Yang… - Medical …, 2019 - Wiley Online Library
Purpose The purpose of this work was twofold:(a) To provide a robust and accurate method
for image segmentation of dedicated breast CT (bCT) volume data sets, and (b) to improve …

Low-dose 3D quantitative vascular X-ray imaging of the breast

PM de Carvalho - 2014 - theses.hal.science
Background: Worldwide, breast cancer is the most common cancer and second deadliest
cancer in women. Diagnostic imaging techniques are a critical part for screening, diagnosis …

Characterization of X-ray scattering for various phantoms and clinical breast geometries using breast CT on a dedicated hybrid system

JP Shah, SD Mann, MP Tornai - Journal of X-ray Science and …, 2017 - content.iospress.com
OBJECTIVE: The purpose of this study was to utilize a dedicated breast CT system using a
2D beam stop array to physically evaluate the scatter to primary ratios (SPRs) of different …

A novel static CT system: The design of triple planes CT and its multi-energy simulation results

Y Yao, L Li, Z Chen - Frontiers in Physics, 2021 - frontiersin.org
In this paper, we propose a novel static CT system: triple planes CT (TPCT) system. Three
source-detector planes in different horizontal directions are placed in the system. Line-array …