Pediatric eye evaluations preferred practice pattern®: I. Vision screening in the primary care and community setting; II. Comprehensive ophthalmic examination

DK Wallace, CL Morse, M Melia, DT Sprunger… - …, 2018 - aaojournal.org
Vision screening for children is an evaluation to detect reduced visual acuity or risk factors
that threaten the healthy growth and development of the eye and visual system. Vision …

Measuring intraocular pressure

KC Okafor, JD Brandt - Current opinion in ophthalmology, 2015 - journals.lww.com
There is no perfect tonometer, and clinicians must choose which to use in their daily
practice, balancing accuracy, precision, convenience, and cost. Clinicians should recognize …

Comparison of contact lens and intraocular lens correction of monocular aphakia during infancy: a randomized clinical trial of HOTV optotype acuity at age 4.5 years …

SR Lambert, MJ Lynn, EE Hartmann… - JAMA …, 2014 - jamanetwork.com
Importance The efficacy and safety of primary intraocular lens (IOL) implantation during early
infancy is unknown. Objective To compare the visual outcomes of patients optically …

Pediatric eye evaluations preferred practice pattern

AK Hutchinson, CL Morse, A Hercinovic… - …, 2022 - pmc.ncbi.nlm.nih.gov
Vision screening for children is an evaluation to detect reduced visual acuity or risk factors
that threaten the healthy growth and development of the eye and visual system. Vision …

Icare home tonometer: a review of characteristics and clinical utility

J Liu, T De Francesco, M Schlenker… - Clinical …, 2020 - Taylor & Francis
Abstract The Icare HOME (TA022, Icare Oy, Vanda, Finland) is rebound tonometer recently
approved by the US Food and Drug Administration in March 2017 designed for self …

Pediatric Glaucoma—From Screening, Early Detection to Management

R Shen, VSW Li, MOM Wong, PPM Chan - Children, 2023 - mdpi.com
Pediatric glaucoma (PG) covers a rare and heterogeneous group of diseases with variable
causes and presentations. Delayed diagnosis of PG could lead to blindness, bringing …

Effect of anesthesia on intraocular pressure measurement in children

M Mikhail, K Sabri, AV Levin - Survey of ophthalmology, 2017 - Elsevier
Measurement of the intraocular pressure (IOP) is central to the diagnosis and management
of pediatric glaucoma. An examination under anesthesia is often necessary in pediatric …

Long-term risk of glaucoma after congenital cataract surgery

SR Lambert, A Purohit, HM Superak, MJ Lynn… - American journal of …, 2013 - Elsevier
Purpose To report the long-term risk of glaucoma development in children following
congenital cataract surgery. Design Retrospective interventional consecutive case series …

[HTML][HTML] Pediatric intraocular pressure measurements: tonometers, central corneal thickness, and anesthesia

MA Fayed, TC Chen - Survey of Ophthalmology, 2019 - Elsevier
Measuring intraocular pressure (IOP) is the cornerstone of a comprehensive glaucoma
examination. In babies or small children, however, IOP measurements are problematic …

Current management of infantile cataracts

PD Lenhart, SR Lambert - Survey of ophthalmology, 2022 - Elsevier
Infantile cataracts remain one of the most treatable causes of lifelong visual impairment.
While the chance of improving vision for children with infantile cataracts has never been …