Improved joint-line restitution in unicompartmental knee arthroplasty using a robotic-assisted surgical technique

Y Herry, C Batailler, T Lording, E Servien… - International …, 2017 - Springer
Purpose Joint-line restitution is one objective of unicompartmental knee arthroplasty (UKA).
However, the joint line is often lowered when resurfacing femoral implants are used. The …

Minor varus alignment provides better results than neutral alignment in medial UKA

M Vasso, C Del Regno, A D'Amelio, D Viggiano… - The Knee, 2015 - Elsevier
Introduction Few data exist regarding the outcome and survivorship of medial UKA in
patients with minor varus alignment. The purpose of this study was therefore to analyse the …

Effect of tibial component alignment on knee kinematics and ligament tension in medial unicompartmental knee arthroplasty

K Sekiguchi, S Nakamura, S Kuriyama… - Bone & Joint …, 2019 - boneandjoint.org.uk
Objectives Unicompartmental knee arthroplasty (UKA) is one surgical option for treating
symptomatic medial osteoarthritis. clinical studies have shown the functional benefits of …

Importance of joint line preservation in unicompartmental knee arthroplasty: finite element analysis

OR Kwon, KT Kang, J Son, DS Suh… - Journal of …, 2017 - Wiley Online Library
Unicompartmental knee arthroplasty (UKA) is an effective surgical technique for pain relief
and functional restoration in patients with localized osteoarthritis of the knee joint. However …

Image-based robotic unicompartmental knee arthroplasty allowed to match the rotation of the tibial implant with the native kinematic knee alignment

C Favroul, C Batailler, R Canetti, J Shatrov… - International …, 2023 - Springer
Purpose Image-based robotic tools improve the accuracy of unicompartmental knee
arthroplasty (UKA) positioning, but few studies have examined its effect on axial alignment …

Eight hundred twenty-five medial mobile-bearing unicompartmental knee arthroplasties: the first 10-year US multi-center survival analysis

OK Alnachoukati, JW Barrington, KR Berend… - The Journal of …, 2018 - Elsevier
Background FDA approval for the Oxford phase III device was approved for use in the United
States in 2004. This study seeks to provide the first long-term, large patient sample size …

High accuracy of component positioning and restoration of lower limb alignment using robotic medial unicompartmental knee arthroplasty

E Diquattro, J Lettner, M Adriani, R Prill… - Knee Surgery …, 2024 - Wiley Online Library
Purpose Unicondylar arthroplasty was performed using robotic medial unicompartmental
knee arthroplasty (R‐mUKA) and gap‐balancing instrumentation. Our hypothesis was that …

Enhancing robotic precision in medial UKA: Image‐based robot‐assisted system had higher accuracy in implant positioning than imageless robot‐assisted system …

S Gaggiotti, C Foissey, T Pineda… - Knee Surgery …, 2024 - Wiley Online Library
Purpose The objective of this study was to compare the degree of accuracy in implant
positioning and limb alignment offered by two robot‐assisted (RA) systems: an image‐based …

Impact of tibial component coronal alignment on knee joint biomechanics following fixed‐bearing unicompartmental knee arthroplasty: a finite element analysis

Y Nie, Q Yu, B Shen - Orthopaedic Surgery, 2021 - Wiley Online Library
Objective Unicompartmental knee arthroplasty (UKA) has indicated a higher rate of revision
than total knee arthroplasty (TKA). The success of UKA depends on UKA component …

Optimization of sagittal and coronal planes with robotic-assisted unicompartmental knee arthroplasty

MA Gaudiani, BU Nwachukwu, JV Baviskar, M Sharma… - The Knee, 2017 - Elsevier
Background One of the anatomic goals of total knee arthroplasty (TKA) is optimizing in the
coronal and sagittal plane. Accurate alignments of both planes have been correlated to …