Non-contact structural health monitoring of a cable-stayed bridge: Case study

MM Alamdari, L Ge, K Kildashti, Y Zhou… - Structure and …, 2019 - Taylor & Francis
In this article, the condition assessment of a cable-stayed bridge using remote sensing is
presented. The displacement influence line (DIL) of the bridge under the live load tests is …

The state of the art in structural health monitoring of cable-stayed bridges

H Li, J Ou - Journal of Civil Structural Health Monitoring, 2016 - Springer
Cable-stayed bridges are a type of long-span bridges that have been extensively
constructed throughout the world. However, cable-stayed bridges suffer from a variety of …

Health monitoring of cable-stayed bridges-A case study

AB Mehrabi, NM Telang, H Ghara… - Structures 2004: Building …, 2004 - ascelibrary.org
Several cable-stayed bridges have shown signs of damages mostly induced by
susceptibility of stay cables to wind-induced vibrations and corrosion. This has caused some …

Investigation concerning structural health monitoring of an instrumented cable-stayed bridge

JM Ko, YQ Ni, HF Zhou, JY Wang… - Structures & Infrastructure …, 2009 - Taylor & Francis
In Hong Kong, a sophisticated long-term structural health monitoring system has been
devised by the Highways Department of HKSAR Government to monitor the structural …

Experimental study of influence line–based damage localization for long-span cable suspension bridges

Q Cai, Z Chen, S Zhu - Journal of Bridge Engineering, 2023 - ascelibrary.org
Influence line (IL)–based damage indices for long-span bridges are investigated in this
study. Their effectiveness is experimentally validated for the first time through the scaled …

Health monitoring of steel box girder bridges using non-contact sensors

M Abedin, AB Mehrabi - Structures, 2021 - Elsevier
This study investigates the behavior of simple and continuous span steel box girder bridges
after various damage scenarios, including bracing failure and girder fracture, and develops …

A multi-way data analysis approach for structural health monitoring of a cable-stayed bridge

MM Alamdari, NL Dang Khoa, Y Wang… - Structural Health …, 2019 - journals.sagepub.com
A large-scale cable-stayed bridge in the state of New South Wales, Australia, has been
extensively instrumented with an array of accelerometer, strain gauge, and environmental …

Bridge condition monitoring under moving loads using two sensor measurements

Z Nie, J Lin, J Li, H Hao, H Ma - Structural Health Monitoring, 2020 - journals.sagepub.com
A novel damage detection approach using only two sensors to detect the damage in beam
bridges subjected to a moving vehicle is proposed in this article. In this approach, a moving …

[HTML][HTML] Abnormal data detection for structural health monitoring: State-of-the-art review

Y Deng, Y Zhao, H Ju, TH Yi, A Li - Developments in the Built Environment, 2024 - Elsevier
Structural health monitoring (SHM) is widely used to monitor and assess the condition and
performance of engineering structures such as, buildings, bridges, dams, and tunnels …

Structural health monitoring of a cable-stayed bridge using regularly conducted diagnostic load tests

HT Al-Khateeb, HW Shenton III, MJ Chajes… - Frontiers in Built …, 2019 - frontiersin.org
The management and maintenance of cable-stayed bridges represents a major investment
of human and financial capital. One possible approach to reducing the cost while …