Stereopsis and contrast

GE Legge, G Yuanchao - Vision research, 1989 - Elsevier
We have measured threshold disparity as a function of the spatial frequency (0.25–20 c/deg)
and contrast (0.02–0.75) of sine-wave gratings. In forced-choice trials, subjects indicated …

Disparity range for local stereopsis as a function of luminance spatial frequency

CM Schor, I Wood - Vision research, 1983 - Elsevier
The disparity range for stereo sensitivity was investigated with spatially filtered bars, tuned
narrowly over a broad range of spatial frequencies. When measured with narrow (high …

The aperture problem in stereopsis

MJ Morgan, E Castet - Vision research, 1997 - Elsevier
Stereoacuity was determined for gratings and gabor patches as their orientation was varied.
Acuity was constant for 1 c/deg and 2 c/deg gratings over the range 0–80 deg when it was …

The effect of contrast on the completeness of binocular rivalry suppression

M Hollins - Perception & psychophysics, 1980 - Springer
Binocular rivalry between orthogonal sine wave gratings was studied by asking subjects to
indicate when they saw just one or the other grating, as opposed to a composite. Using this …

Gender differences in response to spatial frequency and stimulus orientation

LB Brabyn, D McGUINNESS - Perception & Psychophysics, 1979 - Springer
Male and female subjects with normal or corrected-to-normal visual acuity and less than. 25
diopter of corrected astigmatism were asked to make contrast threshold judgments in …

Binocular summation in normal and stereoblind humans

SA Lema, R Blake - Vision research, 1977 - Elsevier
Monocular and binocular contrast thresholds were measured over a range of spatial
frequencies in normal and stereoblind observers. Unlike normal individuals, whose …

How contrast affects stereoacuity

DL Halpern, RR Blake - Perception, 1988 - journals.sagepub.com
Stereoacuity and its dependence on contrast were measured at four spatial frequencies
separated by 1 octave steps. Using a method of adjustment, observers adjusted the retinal …

Perceived contrast in the fovea and periphery

MW Cannon Jr - Journal of the Optical Society of America A, 1985 - opg.optica.org
Subjects estimated the perceived contrast of 2°-diameter sine-wave grating patches for
spatial frequencies of 2, 4, 8, and 16 cycles/deg, at eccentricities from 0° to 40° and contrasts …

Dmax for stereopsis depends on size, not spatial frequency content

LM Wilcox, RF Hess - Vision Research, 1995 - Elsevier
Stereoacuity depends not only on the carrier frequency of Gabor stimuli, but also upon their
size. To determine if this is also the case at large disparities, we have measured the upper …

The imprecision of stereopsis

SP McKee, DM Levi, SF Bowne - Vision research, 1990 - Elsevier
In comparison to lateral judgments of distance, stereoscopic judgments are not precise.
Although stereoacuity thresholds for targets presented in the fixation plane can equal the …