Adaptive distance protection scheme for shunt‐FACTS compensated line connecting wind farm

R Dubey, SR Samantaray… - IET Generation …, 2016 - Wiley Online Library
To improve the performance of the conventional distance protection scheme for
compensated lines with high resistance faults, an adaptive distance protection scheme is …

Performance comparison of distance protection schemes for shunt-FACTS compensated transmission lines

FA Albasri, TS Sidhu, RK Varma - IEEE transactions on Power …, 2007 - ieeexplore.ieee.org
This paper presents a comparative study of the performance of distance relays for
transmission lines compensated by shunt connected flexible ac transmission system …

Performance of distance relays on shunt-FACTS compensated transmission lines

TS Sidhu, RK Varma, PK Gangadharan… - … on Power delivery, 2005 - ieeexplore.ieee.org
This paper presents a study of the performance of distance protection relays when applied to
protect shunt Flexible AC Transmission System (FACTS) compensated transmission lines …

Distance protection of AC grid with HVDC-connected offshore wind generators

L He, CC Liu, A Pitto, D Cirio - IEEE Transactions on Power …, 2013 - ieeexplore.ieee.org
When a transmission line close to points of common coupling (PCCs) experiences a short-
circuit (SC) fault, the fast reactive power control of voltage-source converter-HVDC (VSC …

Mitigation of adverse effects of midpoint shunt-FACTS compensated transmission lines on distance protection schemes

FA Albasri, TS Sidhu, RK Varma - 2007 IEEE power …, 2007 - ieeexplore.ieee.org
This paper presents practical solutions to mitigate the adverse effects on distance protection
schemes when they are used to protect transmission networks that are compensated by …

Fast distance protection scheme for wind farm transmission lines considering RL and bergeron models

Z Hu, B Li, Y Zheng, T Wu, J He, B Yao… - Journal of Modern …, 2022 - ieeexplore.ieee.org
The distributed capacitance of the line becomes larger as the scale of wind farms, the
transmission voltage level, and the transmission distance increase. Hence, the error of the …

Simultaneous impact of unified power flow controller and off‐shore wind penetration on distance relay characteristics

R Dubey, SR Samantaray… - IET Generation …, 2014 - Wiley Online Library
This study presents an analytical approach for finding the possible impacts of flexible AC
transmission system (FACTS) devices such as unified power flow controller (UPFC) and off …

Impact of SVC on the protection of transmission lines

A Ghorbani, M Khederzadeh, B Mozafari - International Journal of Electrical …, 2012 - Elsevier
The impact of Static Var Compensator (SVC) on the apparent impedance seen by the
transmission line distance relay is investigated in this paper. Analytical results are presented …

A fault detection and classification scheme for unified power flow controller compensated transmission lines connecting wind farms

S Biswas, PK Nayak - IEEE Systems Journal, 2020 - ieeexplore.ieee.org
In recent years, there is an increasing trend of integrating large capacity offshore wind farms
into power grids through UPFC compensated TLs for accommodating large flow of power …

UPFC operating characteristics impact on transmission line distance protection

M Khederzadeh - 2008 IEEE Power and Energy Society …, 2008 - ieeexplore.ieee.org
This paper presents the impact of unified power flow controller (UPFC) operating
characteristics on the transmission line protective relay behavior. The impact of the series …