A two-layer active disturbance rejection controller design for load frequency control of interconnected power system

F Liu, Y Li, Y Cao, J She, M Wu - IEEE Transactions on Power …, 2015 - ieeexplore.ieee.org
This letter proposes a two-layer active disturbance rejection control (ADRC) method with the
compensation of estimated equivalent input disturbances (EID) for load frequency control …

Load frequency control in deregulated environments via active disturbance rejection

W Tan, Y Hao, D Li - International Journal of Electrical Power & Energy …, 2015 - Elsevier
Linear active disturbance rejection control (LADRC) method is investigated for the load
frequency control (LFC) of power systems in deregulated environments. The connections …

Decentralized robust disturbance-observer based LFC of interconnected systems

N Vafamand, MM Arefi, MH Asemani… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
This article develops a novel decentralized controller for multi-area secondary load
frequency control (LFC) of power systems. The proposed robust-adaptive approach …

Robust state estimation method for adaptive load frequency control of interconnected power system in a restructured environment

AO Aluko, RP Carpanen, DG Dorrell… - IEEE Systems …, 2020 - ieeexplore.ieee.org
Handling varying uncertainties in renewable energy generation and load demands are
major challenges to the restructured power system environment. This article proposes the …

Decentralised load frequency control for power systems with communication delays via active disturbance rejection

C Fu, W Tan - IET Generation, Transmission & Distribution, 2018 - Wiley Online Library
A decentralised load frequency control (LFC) for multi‐area power systems with
communication delays is studied. Active disturbance rejection control (ADRC) method is …

A robust decentralized load frequency controller for interconnected power systems

L Dong, Y Zhang, Z Gao - ISA transactions, 2012 - Elsevier
A novel design of a robust decentralized load frequency control (LFC) algorithm is proposed
for an inter-connected three-area power system, for the purpose of regulating area control …

Decentralized robust adaptive-output feedback controller for power system load frequency control

MH Kazemi, M Karrari, MB Menhaj - Electrical Engineering, 2002 - Springer
In this paper, a new model reference-decentralized robust adaptive-output feedback
controller is proposed for the load frequency control (LFC) of large-scale power systems with …

Deterministic dynamic state estimation-based optimal LFC for interconnected power systems using unknown input observer

HH Alhelou, MEH Golshan… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
This paper proposes a novel, fully decentralized load frequency control (LFC) approach
based on dynamic state estimation (DSE). The proposed approach employs an unknown …

Deep reinforcement learning based active disturbance rejection load frequency control of multi-area interconnected power systems with renewable energy

Y Zheng, J Tao, Q Sun, H Sun, Z Chen… - Journal of the Franklin …, 2023 - Elsevier
The use of renewable energy to replace traditional coal, oil and natural gas for power
generation is of great significance to the alleviation of environmental pollution and resource …

Load frequency control for multiple-area power systems

Y Zhang, L Dong, Z Gao - 2009 American Control Conference, 2009 - ieeexplore.ieee.org
This paper presents the development and application of an Active Disturbance Rejection
Controller (ADRC) to regulate the frequency error for a three-area interconnected power …